6
WIRING CONVERSIONS
Wiring conversions can be used when replacing the following programmers
with the FP715. Some time controls are connected differently depending on
the type of system they are controlling. Consult the column headed “NOTE
Table A
DANFOSS RANDALL
FP715, CP715
(PUMPED)
MAINS
DHW
OFF
HTG
OFF
DHW
ON
N
L
1
2
3
DANFOSS RANDALL 922/972
N
L
1
4
3
DANFOSS RANDALL 4033
7
6
5
3
4
DANFOSS RANDALL SET 5
N
L
3
6
1
HORSTMANN 423, AMETHYST 7 & 10
2,3
1
4
6
5
HORSTMANN 424 GEM
2,3
1,10
6
9
4
HORSTMANN LEUCITE 423 & 424
2
1
4
8
3
HORSTMANN 425 DIADEM
N
L
3
6
1
HORSTMANN 525 & 527
N
L
3
6
1
HONEYWELL ST669
N
L
7
4
6
HONEYWELL ST6300 & ST6400
N
L
1
2
3
PEGLER SUNVIC SP50/SP100
N
L
1
4
2
POTTERTON EP2000, EP3000
N
L
1
2
3
RANDALL TSR3+3
3,6
7
2
5
1
RANDALL 3033
1,7
6
5
3
4
RANDALL 702
N
L
4
2
3
SANGAMO FORM 1 410 & 414
4,5
6
2
7
1
SANGAMO S409/1
N,1,3
L
-
-
2