Instruction Manual
14 |
P a g e
7.
Error Codes
The error codes are depicted by a number of flashes by the error light in a sequence every
four seconds.
Code
Reason
Solution
1 Flash
Low Voltage
-
Please check the source
voltage to ensure it is above
the cut out. Try lowering the
voltage cut out setting to
LOW.
-
The vehicle cabling may be
inadequate/unsuitable,
please refer to cable
specifications table for
correct cable thickness
(Page 2)
-
Try on a different power
source
2 Flashes
Fan issue
-
Fan is drawing too many
Amps (Over 1 Amp) –
Contact Evakool
3 Flashes
Compressor Start Issues
-
Unplug for 10 Minutes
-
Try on a different power
source.
-
Possible Electronic Box or
compressor fault – contact
Evakool
4 Flashes
The compressor speed is too low
-
Unplug for 10 Minutes
-
Reduce product load inside
unit
-
Move unit to a lower
ambient temperature
-
Clean vents / ensure clear
air flow over compressor
5 Flashes
Ambient Temperature too high
-
Clean vents / ensure clear
air flow
-
Fan Fault – Contact
Evakool
Summary of Contents for EvaKool SupaKool