Workpiece capacity
SAE R13 1 Part Fitting
1 1/2", depending on the fitting
SAE R13 2 Part Fitting
1", depending on the fitting
SAE R12 2 Part Fitting
1 1/4", depending on the fitting
SAE R15 2 Part Fitting
1", depending on the fitting
Industry
2", without flange, depending on fit-
ting
Die type
239
Electric connection
Connection power
4 kW
Supply voltage adjustable
380 V 50/60 Hz, 3 PE
Back-up fuse
400 V: 16 A delayed,
preferably thermal fuses, if circuit
breakers are used these should be
of the class C type
Hydraulic system
Oil volume
approx. 80 l
Oil type
HLP 46, DIN 51524, 10
filtered
System pressure
max. 280 bar
Building prerequisites
Permanent floor loading
Approx. 0.07 kg/mm
2
Floor carrying capacity
Min. 2500 kg/m
2
Floor quality
B25
Evenness
Max. unevenness 5 mm/m
Inclination
max. 5 mm/m
Summary of Contents for ET5025