6.5 Micrometer adjustment
If the measured forming dimensions of the workpiece deviate from
the forming dimensions of the crimping die when the micrometer is
set to zero, the micrometer must be readjusted.
1.
Release the screws on the cover.
2.
Remove the cover (see “Annex” in Section 9).
3.
Loosen the counter-nut (1) of the contact screw (2).
4.
Adjust the contact screw (2).
2.5 revolutions of the contact screw correspond to 1 mm change in
the forming dimension.
V
5.
Remount the enclosure/front panel.
6.
Test the crimping process and readjust if necessary.
Summary of Contents for ET4200
Page 1: ......
Page 3: ......
Page 57: ...9 1 Machine overview...
Page 66: ...Retaining bolt Crimping die profile 262 263 239 266 232 237 554 245 246 247 245 114 4 x x x...
Page 67: ...9 7 Hydraulic diagram...
Page 68: ...9 8 Electric diagram...
Page 69: ......
Page 70: ......
Page 71: ......
Page 74: ......
Page 75: ......
Page 76: ......