Figure 21. BlueGlobe-sealing
2. Cut the cable sheath at the distance A from the end of the cable, see Figure below. Pull the cut
part of the sheath partly (length B is from 10 to 15 mm) off the cable as shown in the gure. The
distance A depends of the length of the cable lug used. Measure with the cable lug that is used
and cut to suitable lenght.
Do not remove the cable sheath completely at this point and do not cut the braid screen of the cable!
Figure 22. Cut lenght of the cable sheath
3. Insert the cable to the cable gland with slight turning motion. This helps the cable go through
the spring inside the cable gland. Push the cable gland against the sheath of the cable as shown in
Figure below.
EM-PMI540-T1500
6. Installation
36 |
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019