1 Grease ll connection (nipple); D-end (+BHS option)
2 Bearing temperature measurement connector, D-end (+BTMP1 option). Type: 4-pin M12 A coded male.
3
Vibration sensor connection points.
Both in the D- and N- end, one on the top and two on the sides.
4
Lifting points.
The two outmost needed for normal lifting.
5
Inner lifting points.
Can be used for additional lifting lug/eye connections and as machine enclosure (power) grounding
connectiuon point when mounted.
6 Grease ll connection (nipple); N-end (+BHS option).
7 Cooling system connections (bores).
8
Mounting foot rails.
Four rails in 90º circular pattern around the frame.
9 Air ventilation plug.
10 Power connection; cable gland (six glands with -DUAL option).
11 Connection boxes (two boxes with -DUAL option).
12
Bearing temperature measurement connector, N-end (+BTMP1 option).
Connected through the connection box. Type: 4-pin M12 A coded male.
13
Cable gland for anti condensation heater connection.
Anti connection heater connector inside the connection box.
14 Low voltage connector (measurement connector), low voltage grounding through the connector metal
body.
15
Grease escape connections, N-end (+BHS option dependent).
One axial and one radial plug (downwards) in the N-end.
16
Leakage connectors.
One leakage connector in both ends.
17
Grease escape connections, D-end (+BHS option dependent).
One axial plug and four radial plugs in 90º angles around the ange in the D-end.
18 D-end ange mounting.
19 Shaft connection.
EM-PMI540-T1500
3. Product overview
16 |
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019
| BC265856800806en-000106
Summary of Contents for EM-PMI540-1500
Page 1: ...User Guide Motor Generator EM PMI540 1500 danfoss com...
Page 69: ......