Rating plate fields (continued)
Insul. class
Temperature rating (class) of insulation of the electric machine according to IEC60034-1
Temp. class
Temperature rating (class) of individual insulation materials of the insulation according to
IEC60034-1
Bear. / D-end Bearing type (types) in the D-end of the electric machine
Bear. / N-end Bearing type in the N-end of the electric machine
Max. pressure Cooling liquid max pressure
CE
CE marking
Tightening torques
Tightening torque tolerance is +/- 5% of the specified tightening torque, unless otherwise
stated.
Use threadlocking adhesive for RST bolts.
Do not install dry screws or other fastening equipment.
Add suitable lubrication, for example Wuerth HSP 1400, to prevent excess friction.
Connection
Torque
Mounting bolts for D-end attachment
40 Nm
Connection box cover plate screws
5 Nm
Cable lug
15 Nm
Tightening torques to use unless otherwise noted
8.8
10.9
12.9
Thread
Nm
Nm
Nm
M5
7
10
11
M6
11
17
19
M8
27
40
47
M10
54
79
93
M12
93
137
160
M14
148
218
255
M16
230
338
395
User Guide
EM-PMI300-T310
Product overview
18 |
©
Danfoss | April 2023
BC265858156812en-000202