Danfoss ECtemp 532
9
Installation Guide
2.
Connect the thermostat according to the connection
diagram.
IP31
-10T30
D532
Mains
220-240V~
Max. Load
15 (1) A
Sensor
N
L
NTC
N
LOAD
L
LOAD
The screen of the heating cable must be connected
to the earth conductor of the power supply cable by
using a separate connector.
Note: Always install the floor sensor in a conduit in
the floor.
3.
Set the maximum floor temperature between 20° and
50°C by turning the screw with temperature indica-
tions in the upper left corner.
4.
Mount and reassemble the thermostat:
• Fasten the thermostat to a flush-mounting box
or a surface-mounting box by driving the screws
through the holes in each side of the thermostat.
• Install the frame and front cover in the reverse
order of disassembly.
5.
Turn on the power supply.