background image

ECtemp 330 (-10 to +10°C)

Installation Guide

8

Warranty

A 2-year product warranty is valid for:

•  thermostats: ECtemp 330 (-10 to +10°C).

Should you, against all expectations, experience a problem with your Danfoss 
product, you will find that Danfoss offers Danfoss warranty valid from the 

date 

of purchase

 on the following conditions: During the warranty period Danfoss 

shall offer a new comparable product or repair the product if the product is 
found to be faulty by reason of defective design, materials or workmanship. The 
repair or replacement.

The decision to either repair or replace will be solely at the discretion of Dan-
foss. Danfoss shall not be liable for any consequential or incidental damages 
including, but not limited to, damages to property or extra utility expenses. No 
extension of the warranty period following repairs undertaken is granted.

The warranty shall be valid only if the WARRANTY CERTIFICATE is completed 
correctly and in accordance with the instructions, the fault is submitted to the 
installer or the seller without undue delay and proof of purchase is provided. 
Please note that the  WARRANTY CERTIFICATE must be filled in, stamped and 
signed by the authorized installer performing the installation (Installation 
date must be indicated). After the installation is performed, store and keep the 
WARRANTY CERTIFICATE and purchase documents (invoice, receipt or similar) 
during the whole warranty period.

Danfoss warranty shall not cover any damage caused by incorrect conditions of 
use, incorrect installation or if installation has been carried out by non-author-
ized electricians. All work will be invoiced in full if Danfoss is required to inspect 
or repair faults that have arisen as a result of any of the above. The Danfoss 
warranty shall not extend to products which have not been paid in full. Danfoss 
will, at all times, provide a rapid and effective response to 
all complaints and inquiries from our customers.

The warranty explicitly excludes all claims exceeding the 
above conditions.

For full warranty text please use QR code

Summary of Contents for ECtemp 330

Page 1: ...ECtemp 330 10 to 10 C Electronic Thermostat Installation Guide electricheating danfoss com ...

Page 2: ...is not liable or bound by warranty if these in structions are not adhered to during installation or service The English language is used for the original instructions Other languages are a translation of the original instructions 2013 Copyright Danfoss A S ...

Page 3: ...h Either a wire sensor or an external air sensor must be used to measure and control the desired temperature The thermostat has a button to adjust the temperature setting with a scale from 10 to 10 C An LED indicator shows standby periods green light and heating periods red light More information on this product can also be found at ectemp danfoss com Table of Contents 1 Introduction 3 1 1 Technic...

Page 4: ...6A 3680W 230V cos φ 0 3 max1A Sensing units NTC 15kOhm at 25 C Sensing values 0 C 25 C 50 C 42kOhm 15kOhm 6kOhm Hysteresis 0 2 C Ambient temperature 10 C to 50 C Lowering in economy periods 5 C Temperature range 10 C to 10 C Cable specification max 1x4mm2 or 2x2 5mm2 Ball pressure temperature 75 C Pollution degree 2 domestic use Type 1C Storage temperature 20 C to 65 C IP class 20 ...

Page 5: ... to the thermostat is turned off before installation Please also note the following The installation of the thermostat must be done by an authorized and qualified installer according to local regulations The thermostat must be connected to a power supply via an all pole disconnection switch The sensor is to be considered as live voltage Have this in mind if the sensor must be extended Always conne...

Page 6: ...binet with DIN rail attachment or a separate DIN attachment accord ing to local regulation on IP classes Do not place the thermostat in a way that it will be exposed to direct sunlight Follow the steps below to mount the thermostat 1 Click the thermostat on to the DIN rail attachment 2 Connect the thermostat according to the connection diagram 10 C to 10 C ...

Page 7: ...ion Guide N L PE The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector Note Always install the floor sensor in a conduit in the floor 3 Turn on the power supply ...

Page 8: ...d correctly and in accordance with the instructions the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided Please note that the WARRANTY CERTIFICATE must be filled in stamped and signed by the authorized installer performing the installation Installation date must be indicated After the installation is performed store and keep the WARRANTY CERTI...

Page 9: ...allation Guide WARRANTY CERTIFICATE The Danfoss warranty is granted to Address Stamp Purchase date Serial number of the product Product Art No Connected output W Installation Date Signature Connection Date Signature Not mandatory ...

Page 10: ...ECtemp 330 10 to 10 C Installation Guide 10 4 Disposal Instruction ...

Page 11: ...ECtemp 330 10 to 10 C Produced by Danfoss 07 2022 088L8058 AQ088786468294en 020303 Danfoss A S Nordborgvej 81 6430 Nordborg Syddanmark Denmark ...

Page 12: ... 8581185 NO EL 5491481 FI SSTL 3531031 ECtemp 330 10 to 10 C 088L0444 220 240V 50 60Hz 10 to 10 C 16A 3680W 230V Product documentation 40 30 20 10 5 6 7 8 330 dM Designed in Denmark for Danfoss A S 080L8058 5 703466 130346 ...