![background image](http://html1.mh-extra.com/html/danfoss/ectemp-130/ectemp-130_installation-manual_3556679004.webp)
ECtemp 130
Installation Guide
4
1.1
Technical Specifications
Operation voltage
220-240V~, 50Hz
Power consumption
Max 5W
Relay:
Resistive load
Inductive load
Max 16A / 3680W @ 230V
cos φ= 0.3 max 1A
Sensing units
NTC 15 kOhm at 25°C
Sensing values:
0 °C
25 °C
50 °C
42 kOhm
15 kOhm
6 kOhm
Hysteresis
± 0,2 °C
Ambient temperature
0 to +30°C
Frost protection temperature 5 °C -
Temperature range
( ) 5–45 °C
Cable specification max
1x4 mm² or 2x2,5 mm²
Ball pressure temperature
75 °C
Pollution degree
Degree 2 (domestic use)
Type
1C
Storage temperature
-20 to +65°C
IP class
30
Protection class
Class II -