Menu
selection
Meaning
Factory set-
ting
SUPPLY
LINE
Shows the actual supply temperature. The calcu-
lated supply temperature to the heating system
group is within brackets.
During hot water production in operating mode
AUX. HEATER the value for HOT WATER STOP + 10°
is shown within brackets.
-
RETURN
LINE
Shows the actual return temperature. The stop
temperature, MAX RETURN is within brackets.
-
BUFFER
TANK
Indicates the buffer tank temperature.
-
HOT WATER Shows the actual hot water temperature.
-
INTEGRAL
Shows the actual calculated value for integral.
-
REFR 1
Shows the actual temperature of refrigerant sen-
sor 1.
-
REFR 2
Shows the actual temperature of refrigerant sen-
sor 2.
-
POOL
(Expansion
card)
Only appears if POOL is selected. Shows the actual
pool temperature.
The set pool temperature is shown in brackets.
-
SHUNT
GROUP
Only appears if SHUNT GROUP is selected. Shows
the actual supply temperature. The calculated
supply temperature to the shunt group is within
brackets.
-
2ND HEAT
CIR.
Shows the temperature of the second heating cir-
cuit if installed by the buffer tank system.
CURRENT
(Expansion
card)
Only appears if CURRENT LIMITER is selected.
Shows the actual current consumption. The set
value for MAX CURRENT is shown between brack-
ets.
-
User manual
VUIFM102
– 23