If the Curve indicator is lit, press or to adjust the entire curve.
▪
Press and move individual curve points:
▪
If the curve indicator is not lit, individual points can be moved separately by pressing and
to the desired temperature.
Confirm the settings with
5.7
System information
Check applicable operating data described in the tables below. The information can be found in the sub-menu
System information
Select System information on the Menu screen:
1. Press
on the Start screen to open the Menu screen.
2. Press System information
Operating data
Sensor
Explanation
Outdoor
Shows the temperature on the outdoor sensor.
System supply line
Shows the temperature on the system supply line.
Desired system supply line
Shows the current system requirement value.
Hot water
Shows the temperature of the hot water sensor, if hot water production is
permitted.
Supply line (HP)
Shows temperature of outgoing radiator temperature from heat pump.
Return line (HP)
Shows temperature of incoming radiator temperature to heat pump.
Brine in
Shows the current temperature of brine in to the heat pump.
Brine out
Shows the current temperature of brine out from the heat pump.
Seasonal integral
Shows the accumulated difference between the outdoor temperature and
the set "seasonal stop" value.
Heating season: start -240, stop +120
Cooling season: start +100, stop -100
Operating time
Explanation
Compressor run time
Shows the number of hours that the compressor has been in operation.
Tap water run time
Shows the number of hours that has been used for hot water production.
External heater run time
Shows the number of hours that the external heater has been activated.
Version information
In the menu Operating data, version information about the control system software is shown.
This information is useful when contacting support.
User Guide
DHP-M
Danfoss Heating Solutions
VUMIB102