Technical Specifications

Operation voltage

220-240V~, 50Hz

Standby power 

consumption

Max 0.25W

Relay:

Resistive load

Inductive load

Max 15A / 3450W @ 230V

cos φ= 0.3 max 1A

Sensing units

NTC 15kOhm at 25°C

Sensing values:

0°C

25°C

50°C

42 kOhm

15 kOhm

6 kOhm

Hysteresis

± 0.4°C

Ambient temperature

-10 to +30°C

Frost protection 

temperature

5 °C - 

Temperature range

( ) 5-45°C with floor 

sensor only

Cable specification max

1x4mm² or 2x2,5mm²

Ball pressure temperature

75 °C

Pollution degree

2 (domestic use)

Summary of Contents for DEVIreg 530

Page 1: ...www DEVI com Installation Guide DEVIreg 530 Electronic Thermostat...

Page 2: ...DEVIreg 530 Installation Guide 2 The English language is used for the original instructions Other languages are a translation of the original instructions Directive 2006 42 EC...

Page 3: ...ermostat has a button for adjusting the temperature setting with a scale from 1 to 6 each step corresponds to approximately 8 C Furthermore it has a LED indicator showing standby periods green light a...

Page 4: ...e load Max 15A 3450W 230V cos 0 3 max 1A Sensing units NTC 15kOhm at 25 C Sensing values 0 C 25 C 50 C 42 kOhm 15 kOhm 6 kOhm Hysteresis 0 4 C Ambient temperature 10 to 30 C Frost protection temperatu...

Page 5: ...730 2 9 thermostat 1 2 Safety Instructions Make sure the mains supply to the thermostat is turned off before installation IMPORTANT When the thermostat is used to control a floor heating element in co...

Page 6: ...voltage Have this in mind if the sensor must be extended Always connect the thermostat to continuous power supply Do not expose the thermostat to moisture water dust and excessive heat 2 Mounting Inst...

Page 7: ...uce the risk of over heating the floor Place the floor sensor in a conduit in an appropriate place where it is not exposed to sunlight or draft from door openings Equally distant and 2cm from two heat...

Page 8: ...llow the steps below to mount the thermostat 1 Open the thermostat devireg 550 3 5 6 2 4 20 30 40 50 Press the release tab in the bottom of the thermostat using a flat object Carefully detach the fron...

Page 9: ...ernal timer to the terminal marked by a moon symbol and by using for example the same phase as for the mains power supply the thermostat can be set to reduce the temperature by 5 C during specified pe...

Page 10: ...of disassembly 4 Turn on the power supply 3 Settings How to change the minimum and maximum floor temperatures 1 Remove the adjustment button 2 Move the pins to the desired positions 3 Put the adjustm...

Page 11: ...e control may be less accurate and you risk overheating the floor Thermal resistance m K W Examples of flooring Details Approximate setting for 25 C on top surface of floor 0 05 8 mm HDF based laminat...

Page 12: ...ance with the instructions the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided Please note that the WARRANTY CERTIFICATE must be filled in stamp...

Page 13: ...on Guide 13 WARRANTY CERTIFICATE The DEVIwarranty is granted to Address Stamp Purchase date Serial number of the product Product Art No Connected output W Installation Date Signature Connection Date S...

Page 14: ...DEVIreg 530 Installation Guide 14 5 Disposal Instruction...

Page 15: ...DEVIreg 530 08090901 AN417535815906en 010102 Danfoss 2023 03 Danfoss A S Nordborgvej 81 6430 Nordborg Syddanmark Denmark...

Page 16: ...H DEVIreg 530 ELKO 140F1031 Thermostat Floor Sensor ELKO 220 240V 50 60Hz 5 to 45 C 15A 3450 230V IP 31 Product Documentation Designed in Denmark for Danfoss A S 08090901 5 703466 209004 SE EL 85 811...