Implement pump
DDC20/24 implement pump removal
1. Position the pump with the shaft end pointing down.
2. Remove cap screws (K200/K210). Remove the implement pump housing (K150).
3. Remove and discard O-ring (K100/K110).
4. Remove gerotor (K010). Remove locating pins (K250) from housing.
Remove implement pump
K210
K200
K250
K100
K110
K010
K150
Implement pump cover bolts
Item
Description
Wrench size
Torque
K200
Cap screw
8 mm internal hex
60 N
・
m [44 lbf
・
ft]
K210
Cap screw
8 mm internal hex
39 N
・
m [29 lbf
・
ft]
Service Manual
DDC20/24 Axial Piston Pumps
Minor repair
16 |
©
Danfoss | August 2019
L1120413 | AX00000135en-000401