D
GB
F
E
© Danfoss | Climate Solutions | 2023.12
AQ452526009526en-000401| 7
/
HG
2 4
110- 4
CO
2
X
2.3 Type key
(example)
Transcritical
CO
2
version
Compressor version ³
)
Number of poles
Swept volume
Number of cylinders
Size
Oil charge ²
)
Series ¹
)
T
S
1
Type designation
2
Machine number
3
maximum operating current
4
Starting current (rotor blocked)
5
ND (LP): max. admissible operating
pressure
(g)
Low pressure side
HD (HP): max. admissible operating
pressure
(g)
High pressure side
Observe the limits of application
diagrams!
50 Hz
60 Hz
6
Voltage, circuit, frequency
7
Nominal rotation speed
8
Displacement
9
Voltage, circuit, frequency
10 Nominal rotation speed
11 Displacement
12
Oil type filled at the factory
13 Terminal box protection type
Electrical accessories can change
the IP protection class!
}
}
2.2 Name plate
(example)
Fig. 3
2
|
Product description
¹
)
HG - Hermetic Gas-Cooled (suction gas-cooled)
²
)
X
- Ester oil charge
³
)
ML - Normal cooling and deep freezing at low and medium evaporation temperatures
S - For frequency regulation and extended limits of application
SH - For high evaporating temperatures eg. heat pumps, different oil charge
1
2
3
4
5
13
12
7
11
6
10
8
9
HGX24/70-4 S CO
2
T
31,0/17,9A
169A
98A
BC12345A001
Bock GmbH, Benzstr. 7
72636 Frickenhausen, Germany
6,0
7,2
IP66
100/150 bar
BOCK
BOCK
lub E85