background image

VICUJ212 

Produced by Danfoss Floor Heating Hydronics 03/2015

Danfoss can accept no responsibility for possible errors in catalogues, brochures and 

other printed material. Danfoss reserves the right to alter its products without notice. 

This also applies to products already on order provided that such alterations can be 

made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and 

the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Summary of Contents for BasicPlus2 WT-D

Page 1: ...Installation Guide BasicPlus2 WT D WT P Room Thermostats ...

Page 2: ...see fig 2 4 Connect the wire before mounting the back plate to the wall box using the enclosed screws Then mount the cover to the back plate see fig 3 2 Wiring Dimensions see fig 4 Wiring diagram see fig 5 S1 S2 floor sensor terminals WT D P is often used with Danfoss TWA actuator Depending on the conditions of power location and actuator type NC or NO the wiring between room thermostat and actuat...

Page 3: ...and N before wiring is recommended 2 Don t remove too much of the insulation cover from the wire to avoid short circuit caused by the naked wire touching the metal 86 size mounting wall box 3 Don t let the screw press or touch the wire when using screw to fix room thermostat in wall box A short circuit risk exists if the wire insulation cover is damaged by the screw and if the naked wire con nects...

Page 4: ...e by hanging towels directly in front of it 7 The room thermostat should be connected to the corresponding loop actuator in individual room temperature control 5 Technical Specifications Feature Description Approval CE Marking EN60730 Ambient temperature 10 60 C IP Class 30 Max load inductive 1 A Max load resistive 3 A Power consumption 2 W Power supply 85 250 Vac 50 60 Hz Room temp set range 5 35...

Page 5: ...Danfoss Heating Solutions VICUJ212 5 Installation Guide BasicPlus2 WT D WT P Fig 1 1 5 m Fig 2 Fig 3 ...

Page 6: ...VICUJ212 Danfoss Heating Solutions 6 Installation Guide BasicPlus2 WT D WT P Fig 4 86 0 86 0 24 5 16 0 50 0 50 0 Fig 5 S2 S1 N NC NO L 230 V Fig 6 N 230 V L TWA 230V NC WT D P L NO NC N S1 S2 ...

Page 7: ...g Solutions VICUJ212 7 Installation Guide BasicPlus2 WT D WT P Fig 7 N 230 V L TWA 230V NO WT D P L NO NC N S1 S2 Fig 8 N 230 V L TWA 230V NC WT D P L NO NC N S1 S2 Fig 9 N 230 V L TWA 230V NO WT D P L NO NC N S1 S2 ...

Page 8: ...eserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respective companies Danfoss and the Danfoss logotype are trademarks of Danfoss A S All rights reserved ...