30 | 180R9264 | AQ115586503043en-000903
© Danfoss | 2023.03
Operating guide
Installation, Operation and Maintenance APP 11-13
11. Dimensions with motor
unit
The examples of assemblies with motor are only
for IEC motors and couplings. Please make sure
to check required motor power and dimensions
when selecting size of pump and motor. For ad-
vice and calculation tool, please contact Danfoss.
11.3 APP 11.0-13.0
Pump
A mm
(inch)
B mm
(inch)
C mm
(inch)
D mm
(inch)
E mm
(inch)
F mm
(inch)
G mm
(inch)
IEC Electric motor
APP 11
350
(13.78)
473
(18.62)
180
(7.09)
279
(10.98)
241
(9.49)
578
(22.76)
204
(8.03)
22 kW, IEC 180L-4
APP 11
400
(15.75)
513
(20.20)
200
(7.87)
318
(12.52)
305
(12.01)
659
(25.94)
204
(8.03)
30 kW, IEC 200L-4
APP 13
450
(17.72)
561
(22.09)
225
(8.86)
356
(14.02)
286
(11.26)
667
(26.26)
234
(9.21)
37 kW, IEC 225S-4
Data sheet