22 | 180R9264 | AQ115586503043en-000903
© Danfoss | 2023.03
Operating guide
Installation, Operation and Maintenance APP 11-13
4.4 APP 11-13
Pump size
APP 11/1200
APP 11/1500
APP 13/1200
APP 13/1500
Code number APP
180B3212
180B3211
180B3214
180B3213
Code number APP ATEX
3)
180B3222
180B3221
180B3224
180B3223
Geometric
displacement
cm³/rev.
166.4
137.4
197.5
166.4
in³/rev.
10.15
8.38
12.05
10.15
Pressure
Max. outlet
1)
pressure
continuous
barg
83
70
83
70
psig
1200
1015
1200
1015
Min. outlet
1)
pressure
barg
10
10
10
10
psig
145
145
145
145
Inlet pressure
continuous
barg
2 - 5
2 - 5
2 - 5
2 - 5
psig
29 - 72.5
29 - 72.5
29 - 72.5
29 - 72.5
Max. inlet
pressure. peak
barg
10
10
10
10
psig
145
145
145
145
Speed
Min. speed
continuous
rpm
700
700
700
700
Max. speed
continuous
rpm
1200
1500
1200
1500
Typical flow - Flow curves available in item 5
1000 rpm at
max. pressure
m³/h
9.22
7.50
11.07
9.23
1500 rpm at
max. pressure
m³/h
11.25
13.84
1200 rpm at
max. pressure
gpm
48.71
39.61
58.51
48.75
Technical specifications
Media
2)
temperature
°C
2 - 50
2 - 50
2 - 50
2 - 50
°F
35.6 - 122
35.6 - 122
35.6 - 122
35.6 - 122
Ambient
temperature
°C
0 - 50
0 - 50
0 - 50
0 - 50
°F
32 - 122
32 - 122
32 - 122
32 - 122
Weight (dry)
kg
78
78
78
78
lb
172
172
172
172
Sound pressure
level
4)
dB(A)
85
85
85
85
Footprint with
IEC motor
5)
m²
0.48
0.48
0.54
0.54
foot²
5.17
5.17
5.81
5.81
Typical motor size
Max. speed at
max. pressure
kW
30.0
37.0
1200 rpm at
max. pressure
HP
40.0
50.0
Torque at max.
outlet pressure
Nm
229
166
274
204
lbf-ft
169
123
202
150
1)
For lower and higher pressure, please contact Danfoss.
2)
Dependent on the NaCI concentration - see chapter 8.
4)
Category 2, Zone 1 or Category 3, Zone 2.
4)
A-weighted sound pressure level at 1 m from the pump unit
surfaces (reference box) acc. to EN ISO 20361 section 6.2.
The noise measurements are performed acc. to EN ISO 3744:2010
on a motor-pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
Data sheet