6.1 Periodic maintenance
The APP pump is designed so that lubrication
follows from the water itself and there is thus no
oil in the pump.
The pump requires no periodic replacements of
seals and valve parts.
6.2 Repair
In case of irregular function in the pump, please
contact the Danfoss Sales Organisation.
6.
Service
5.5.2 Open-ended systems with direct water
supply
1.
Disconnect the water supply to the pump.
2.
Through the lower bleeding plug, empty
the pump housing of water and close it
again.
3.
Connect the pump to a tank of e.g. 25 litre
6 gal. of anti-freeze additive. Connect a
hose to the inlet port of the pump and via
another hose return the
fl
ow from the
outlet port to the tank with anti-freeze
additives.
4.
Quickly start and stop the pump. Make sure
that the pump does not run dry. The pump
is now protected against internal corrosion
and frost.