background image

6 | © Danfoss | 2016.09

VI.LF.E3.5B 

AME 445

AME 445 + VRB 2, VRG 2

L

H

H

1

A

Min 20,5

L

H

H

1

B

Min 20,5

AME 445 + VRB 2

L

H

H

1

A

Min 20,5

AME 445 + VRB 3, VRG 3

L

H

H

1

B

Min 20,5

AME 445 + VRB 3

min. 20,5

H

H

1

L

AME 445 + 

VF 3, VL 3 (DN 15-80)

82,5

m

in

. 18

0

147

15

9,

5

G

R

P

H

H

1

L

min. 20,5

AME 445 + 

VF 2, VL 2 (DN 15-80)

Type

DN

Connection

H

H

1

Rp

G

mm

VRB 2

15

½

1

80

25

191

20

¾

11/4

80

29

194

25

1

11/2

95

29

197

32

11/4

2

112

33

202

40

11/2

21/4

132

43

213

50

2

2 ¾

160

47

217

VRB 3

15

½

1

80

40

191

20

¾

11/4

80

45

194

25

1

11/2

95

50

197

32

11/4

2

112

58

202

40

11/2

21/4

132

75

230

50

2

2 ¾

160

83

243

Type

DN

Connection

H

H

1

G

mm

VRG 2

15

1

80

29

191

20

11/4

80

31

193

25

11/2

95

32

197

32

2

112

35

201

40

21/4

132

45

213

50

2 ¾

160

48

217

VRG 3

15

1

80

40

191

20

11/4

80

45

193

25

11/2

95

50

196

32

2

112

58

201

40

21/4

132

75

230

50

2 ¾

160

83

243

Type

DN

L

H

VF

H

VL

H1

mm

VF 2
VL 3

15

130

47,5

40

191

20

150

52,5

45

194

25

160

57,5

50

197

32

180

70

60

202

40

200

75

65

213

50

230

82,5

70

218

65

290

92,5

88

254

80

310

100

95

258

Type

DN

L

H

H1

mm

VF 3
VL 3

15

130

63

191

20

150

70

194

25

160

75

197

32

180

80

202

40

200

90

230

50

230

100

243

65

290

120

254

80

310

155

270

Summary of Contents for AME 445

Page 1: ...nfoss 2016 09 VI LF E3 5B 1 ENGLISH AME 445 www danfoss com Page 6 DEUTCH AME 445 www danfoss de Seite 7 AME 445 Operating Guide AME 445 AME 445 AME 445 AME 445 VRB 2 VRG 2 VRB 3 VRG 3 VF 2 VL 2 VF 3 VL 3 ...

Page 2: ...2 Danfoss 2016 09 VI LF E3 5B AME 445 5 95 RH no condensing MAINTENANCE FREE 4 6mm 1mm Click ...

Page 3: ...aus dem LOCK MODUS Flashing green LED Self stroking mode RESET MODE period is every second Constant green LED Positioning mode Flashing green LED Setpoint is reached period is every 6 seconds Flashing red LED STAND BY mode period is every two seconds Grüne LED blinkt automatische Hubanpassung Intervall jede Sekunde Dauerhaft grün leuchtende LED Positionierungsmodus Grüne LED blinkt Sollwertpositio...

Page 4: ...4 Danfoss 2016 09 VI LF E3 5B AME 445 60 ON OFF Click 100 FULL ...

Page 5: ... Danfoss 2016 09 5 VI LF E3 5B AME 445 ...

Page 6: ...91 20 11 4 80 45 194 25 1 11 2 95 50 197 32 11 4 2 112 58 202 40 11 2 21 4 132 75 230 50 2 2 160 83 243 Type DN Connection L H H1 G mm VRG 2 15 1 80 29 191 20 11 4 80 31 193 25 11 2 95 32 197 32 2 112 35 201 40 21 4 132 45 213 50 2 160 48 217 VRG 3 15 1 80 40 191 20 11 4 80 45 193 25 11 2 95 50 196 32 2 112 58 201 40 21 4 132 75 230 50 2 160 83 243 Type DN L HVF HVL H1 mm VF 2 VL 3 15 130 47 5 40 ...

Page 7: ...een LED blinks causes the actuator to start self stroking procedure The bi colour LED flashes green at 1 sec intervals during calibration procedure which begins by extracting the stem When the maximum force is detected at the valve end position the actuator then retracts the stem until the maximum force is once again detected on the other valve end position The actuator will then automatically ent...

Page 8: ...LED Automatische Hubanpassung RESET MODUS Durch Drücken der STAND BY RESET LOCK Taste für 6 9 Sek und Loslassen nach 2x Blinken der grünen LED beginnt der Stellantrieb die automatische Hubanpassung Die zweifarbige LED blinkt während des Kalibriervorgangs der mit dem Ausfahren der Antriebsstange beginnt in 1 Sekunden Intervallen grün Wenn die maximale Kraft erkannt wird in der Ventilendlage fährt d...

Reviews: