AK-CC 550
Instructions RI8LN802 © Danfoss 2/2012
9
Continued
Code
1 2 3
4
5 6 7
8
9 10
Min.
Max.
Fac.
Actual
Fan cutin during defrost
0: Stopped
1: Running
2: Running during pump down and defrost
d09
1
1
1
1
1
1
1
1
1
1
0
2
1
Defrost sensor:
0 =Stop on time, 1=S5, 2=S4, 3=Sx
(Application 1-8 and 10: both S5 and S6.
Application 9: S5 and S5B)
d10
1
1
1
1
1
1
1
1
1
1
0
3
0
Pump down delay
d16
1
1
1
1
1
1
1
1
1
1
0 min.
60 min.
0
Drain delay (used at hot gas defrost only)
d17
1
0 min.
60 min.
0
Max. aggregate refrigeration time between two defrosts
d18
1
1
1
1
1
1
1
1
1
1
0 hrs
48 hrs
0/OFF
Heat in drip tray. Time from defrosting stops to heating
in the drip tray is switched off
d20
1
0 min.
240 min.
30
Extra defrost with adaptive function allowed:
0=none, 1=monitoring only, 2=Day only, 3=Both day
and night, 4=Night only
d21
1
1
1
1
1
1
1
1
1
1
0
4
0
Reset of the "Adaptive defrosting function" (starts a
defrost and starts subsequent new tuning)
d22
1
1
1
1
1
1
1
1
1
1
0/OFF
1/ON
0/OFF
Injection control function
Injection algorithm
Only for trained personnel
n05
1
1
1
1
1
1
1
1
1
1
30 sec
600 sec
150
Max. value of superheat reference
n09
1
1
1
1
1
1
1
1
1
1
3°C
20°C
12
Min. value of superheat reference
n10
1
1
1
1
1
1
1
1
1
1
3°C
20°C
3
MOP temperature. Off if MOP temp. = 15.0 °C
n11
1
1
1
1
1
1
1
1
1
1
-50°C
15°C
15
Glide for Ezotrope refrigerant (at S1-measurement only)
n12
1
1
1
1
1
1
1
1
1
1
0 K
10 K
0
Period time of AKV pulsation
Only for trained personnel
n13
1
1
1
1
1
1
1
1
1
1
3 sec
6 sec
6
Injection algorithm
Only for trained personnel
n15
1
1
1
1
1
1
1
1
1
1
30 sec
600 sec
180
Injection algorithm
Only for trained personnel
n16
1
1
1
1
1
1
1
1
1
1
10 %
75 %
30
Injection algorithm
Only for trained personnel
n17
1
1
1
1
1
1
1
1
1
1
5 %
70 %
30
Injection algorithm
Only for trained personnel
n18
1
1
1
1
1
1
1
1
1
1
0
10
4
Injection algorithm
Only for trained personnel
n23
1
1
1
1
1
1
1
1
1
1
1
50
6
Injection algorithm
Only for trained personnel
n24
1
1
1
1
1
1
1
1
1
1
100 sec
1800 sec
900
Selection of signal to superheat measurement: 1=
pressure transmitter AKS32R, 2= Temperature sensor S1
n57
1
1
1
1
1
1
1
1
1
1
1
2
1
Fan
Fan stop temperature (S5)
F04
1
1
1
1
1
1
1
1
1
1
-50°C
50°C
50
Pulse operation on fans: 0=No pulse operation, 1=At
thermostat cuts out only, 2= Only at thermostat cut
outs during night operation
F05
1
1
1
1
1
1
1
1
1
1
0
2
0
Period time for fan pulsation (on-time + off-time)
F06
1
1
1
1
1
1
1
1
1
1
1 min.
30 min.
5
On-time in % of period time
F07
1
1
1
1
1
1
1
1
1
1
0 %
100 %
100
Real time clock
Six start times for defrost.
Setting of hours.
0=OFF
t01 -
t06
1
1
1
1
1
1
1
1
1
1
0 hrs
23 hrs
0
Six start times for defrost.
Setting of minutes.
0=OFF
t11 -
t16
1
1
1
1
1
1
1
1
1
1
0 min.
59 min.
0
Clock - Setting of hours
t07
1
1
1
1
1
1
1
1
1
1
0 hrs
23 hrs
0
Clock - Setting of minute
t08
1
1
1
1
1
1
1
1
1
1
0 min.
59 min.
0
Clock - Setting of date
t45
1
1
1
1
1
1
1
1
1
1
1 day
31 day
1
Clock - Setting of month
t46
1
1
1
1
1
1
1
1
1
1
1 mon.
12 mon.
1
Clock - Setting of year
t47
1
1
1
1
1
1
1
1
1
1
0 year
99 year
0
Miscellaneous
Delay of output signals after start-up
o01
1
1
1
1
1
1
1
1
1
1
0 sec
600 sec
5
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function with alarm
when open. 3=door alarm when open. 4=defrost start
(pulse-signal). 5=ext.main switch. 6=night operation
7=thermostat band changeover (activate r21). 8=alarm
function when closed. 9=alarm function when open.
10=case cleaning (pulse signal). 11=forced cooling at hot
gas defrost,
12=night cover
o02
1
1
1
1
1
1
1
1
1
1
0
12
0