489±2.5 mm [19.3±0.10 in]
330±1.0 mm [13±0.04 in]
378±1.0 mm [14.9±0.04 in]
12±1.0 mm [0.5±0.04 in]
157±1.0 mm [6.2±0.04 in]
157±1.0 mm [6.2±0.04 in]
240±1.0 mm [9.4±0.04 in]
577±2.5 mm [22.7±0.10 in]
9.0±2.5 mm [0.4±0.10 in]
9.0±2.5 mm [0.4±0.10 in]
621±2.5 mm [24.4±0.10 in]
621.5±2.5 mm [24.5±0.10 in]
55.5±1.0 mm [2.2±0.04 in]
353
±
1.0 mm [13.9
±0.04 in]
338.5
±
1.0 mm [13.3
±0.04 in]
e30be404.10
PE M8 (15Nm)
8 holes must be used to fix the AHF
with M8 screws
Illustration 7.16 IP20 X4-V3 External Fan
A
B
X1.1
X1.2
X1.3
X2.1
X3.1
X4.1
X3.2
X4.2
X3.3
X4.3
X2.2
X2.3
e30be405.10
X1 Mains 35mm(4Nm)
X2 Drive 35mm(4Nm)
X3/X4 Capacitor disconnect 16mm(3.5Nm)
A/B Temperature 2.5mm(0.8Nm)
Illustration 7.17 IP20 X4-V3 External Fan, Terminal Designation and 3D View
Specifications
VLT
®
Advanced Harmonic Filter AHF 005/AHF 010
72
Danfoss A/S © 05/2019 All rights reserved.
MG80C602
7
7
Summary of Contents for AHF 010
Page 2: ......