5. Remove the setting lug (F24) from inside of end cap.
End cap components
F24
(080)
F24
(060)
F30
(060)
F28
F26
F26
F28
End cap
(typical for 060 and 080 frame sizes)
axial port style shown
G10
F28
F26
G80
G80A
3 mm (060)
3 mm (060)
060: 3/8 inch
080: 9/16 inch
5 mm (080)
F10
F10
F12
F12
F11
F11
P104 089
080 frame
1. Remove end cap plug (G80).
2. Remove lock screw (F28).
3. Remove cone-point set screw (F26).
4. Remove feedback fork / setting lug (F24) through hole in end cap.
110 - 250 frame
1. Remove lock screw (F28).
2. Remove cone-point set screw (F26).
Repair Instructions