Repair
Removing the Solenoid Valve
It is not necessary to remove the valve unless it is being replaced.
Individual parts are not available. Replace entire valve.
Solenoid for J1, J2
If replacing the valve, use a 7/8 wrench to remove the valve from the housing.
Solenoid for J3, J4
If replacing the valve, use a 3 mm internal hex wrench to remove screws (M15). Remove the valve.
Control Disassembly
F32
F324
M24
T6
T4
M23
M23A
M24
U7
N84
M21
M18
M16
M14
M20
N34
N33
N33
N34
M22
M24
M24A
M22A
M24
M24
U6
M151
M150
M1
Z*
G38
G42
G38
G42
G36
N32
M22
M22A
M15
M1
Note: Orifices (T4 and T6) and
PCOR adjuster (Z*) are
not included in control
J1, J2
J3, J4
The difference
between J3, J4 and
J1, J2 is the way the solenoid
valve is attached to the housing
P106 406E
N240
Legend
Item
Wrench size
Torque
M15
3 mm internal hex
2.8 Nm [1 lbf•ft]
M1 (J1, J2)
7/8
20 Nm [15 lbf•ft]
M150, M151
(80, 110)
8 mm internal hex
78 Nm [58 lbf•ft]
Service Manual
Series 51 Hydraulic Proportional Controls Service Manual
J1, J2, J3, J4 Controls
11009446 • Rev BA • July 2014
33