Optional PCOR Housing
Disassembly
1. Remove plugs (N27). Remove and discard O-rings (N27A).
2. Using a 1 inch wrench, remove plug (N23). Remove and discard O-ring (N23A).
3. Remove locknut (N14).
4. Remove adjustment plug (Z00). Remove and discard O-ring (N16J).
5. Remove spring (N18).
6. Remove spool and spring guide assembly (N20).
7. Remove screws (N29).
8. Remove and discard O-rings (N24P, N82).
9. If present, remove orifices (U6, U7).
PCOR
N82
N29
N20
N14
N18
N16J
Z00
N87
U6
U7
N24P
P106 384E
N23
N27
N27
Legend
Item
Wrench size
Torque
N27
1/8 inch internal hex
7 Nm [4 lbf•ft]
N23
1 inch
40 Nm [30 lbf•ft]
U6, U7
3 mm internal hex
6 Nm [4 lbf•ft]
N29
5 mm internal hex
16 Nm [12 lbf•ft]
N14
1-5/16 inch
N/A
Inspection
Clean and inspect components for damage or foreign material. Replace damaged parts.
Assembly
1. If previously removed, use a 3mm internal hex wrench to install orifices (U6, U7). Torque to 6 N•m [4
lbf•ft].
2. Using petroleum jelly to retain them, install new interface O-rings (N24P, N82).
3. Position PCOR on multiblock. Install screws (N29). Torque using a 5 mm internal hex wrench to 16
N•m [12 lbf•ft].