Using the Programmer
The selector switch is used to select how the 3060 controls
your hot water and heating. The heating and hot water can be
operated together in various combinations, or the water can
be controlled on its own (i.e. during the summer when only
hot water is required).
There are six positions into which the selector switch may
be set.
1 -
H OFF / W OFF
Both Heating and Hot Water will remain OFF until you
change the setting.
2 -
H TWICE / W TWICE
In this position the Heating and Hot Water will both
come on and go off according to the times you have
programmed (ON at A, OFF at B, ON at C, OFF at D).
3 -
H ONCE / W ONCE
This setting overrides tappets B and C, so both
Heating and Hot Water will switch ON at the time
marked by tappet A and will stay on until the time
marked by tappet D. Both services will then switch