Settings:
Name
Default
Max value
Min value
Step
Unit
ECO mode
OFF
ON
OFF
1
ECO speed BD350GH
2500
4000
2500
1
rpm
ECO temperature
25
40
-40
0.1
Celsius (°C)
Automatic
ECO temperature
1
1
0
1
0 = OFF
1 = ON
4.2.7 ECO function
Operation in ECO mode reduces energy consumption and noise by controlling compressor speed as a
function of temperature. ECO mode can be selected only when using an NTC temperature sensor.
In ECO mode,
• when operating below ECO temperature, compressors run at the set ECO speed, and the
Start
speed
setting will be overruled, if it differs from ECO speed.
• when operating above ECO temperature, the compressors run at Requested speed.