Page 1: ...MAKING MODERN LIVING POSSIBLE BD Controller 101N07xx Series 24 V DC with Tool4Cool LabEdition software Operating Instructions...

Page 2: ...Operating Instructions BD Controller 101N07xx Series 24 V DC 2 DEHC PS 100 I 02...

Page 3: ...s 4 1 Parameter Overview 13 4 2 Description of Parameters 15 4 2 1 Main Functions 15 4 2 2 Battery protection 15 4 2 3 Compressorn 16 4 2 4 Condenser fan 17 4 2 5 Evaporator fan 17 4 2 6 Thermostat 18...

Page 4: ...4...

Page 5: ...erating conditions are High Back Pressure HBP 1 3 Functions The main functions of BD350GH compressor systems are Motor Compressor speed control Thermostat control ON OFF or electronic via NTC temperat...

Page 6: ...6...

Page 7: ...D electronic controller 101N07xx Series 24V DC 101N0715 101N0710 discontinued Tool4Cool LabEdition software installation CD NTC temperature sensor alternative mechanical thermostat DC line cords Produ...

Page 8: ...Gateway Terminal plug USB only for supply COM USB Danfoss One Wire LIN Gateway One Wire LIN USB Code n o 105N9501 RS232 485 USB 2 0 Electronics One Wire LIN RS232 RS485 Tx Rx option 2 option 1 USB 2...

Page 9: ...er output pulse width modulated Fc Condenser fan optional 24 V DC 0 24 V max 40 Watt power output pulse width modulated Main supply voltage Nominal voltage 24 V DC range 17 to 31 5 V DC Size Max lengt...

Page 10: ...10...

Page 11: ...350GH compressor is shown below Example 3 2 Operation The Tool4Cool software enables the user to observe and document certain aspects of the compressor operation via the controller The output of the s...

Page 12: ...12...

Page 13: ...nt Condenser fan Cond Fan voltage Supply voltage to the condenser fan 24 31 12 1 Volt Setting Fan speed Condenser fan speed synchronized with compressor operation 100 100 40 10 Setting Fan start delay...

Page 14: ...ostat Auto Electronic Setting Cutout temperature Compressor cuts out below cutout temperature 25 40 40 1 Celsius C Setting Difference 3 15 1 1 Kelvin K Setting Forced ON Force thermostat operation to...

Page 15: ...ve NTC temperature sensor monitoring active Auxiliary temperature sensor monitoring active PCB inverter temperature monitoring active 4 2 2 Battery protection The battery protection serves to avoid pe...

Page 16: ...or Speed limits are min 1850 rpm max speed 4300 rpm If the compressor speed falls below the minimum or exceeds the maximum speed the compressor will stop and an alarm Min speed failure or Max speed fa...

Page 17: ...40 0 1 Seconds Fan forced ON OFF ON OFF 1 Detect missing fan OFF ON OFF 1 Name Description Step Unit Fan speed Actual fan speed 1 4 2 5 Evaporator fan The speed of the evaporator fan can be controlled...

Page 18: ...recommended for the temperature range 60 C to 100 C A mechanical thermostat is recommended for temperatures below 60 C and above 100 C Note An NTC sensor error is not detectable when the NTC sensor i...

Page 19: ...1 1 0 1 0 OFF 1 ON 4 2 7 ECO function Operation in ECO mode reduces energy consumption and noise by controlling compressor speed as a function of temperature ECO mode can be selected only when using a...

Page 20: ...long as cool ing is requested The function will stop the compressor after a certain time Communication time out when there is no contact to the master controller The stop is realized through the Main...

Page 21: ...vent damage to the refrigeration system This parameter is on view in all parameter groups Output Measurements Name Description Vendor name Product code no Software version Unit ID Production date Lot...

Page 22: ...uality of the soldered joints will be endangered When the unit reaches 100 C the system will shut down and an alarm error Alarm 6 Thermal failure will be sent The system restarts automatically after t...

Page 23: ...Operating Instructions BD Controller 101N07xx Series 24 V DC 23 DEHC PS 100 I1 02...

Page 24: ...24...

Page 25: ...Wire LIN gateway with cables driver 105N9501 accessories Industrial Pack I Pack Electronic control unit 24 V DC 101N0714 36 pcs Communication cable 1500 mm AMP connector 105N9545 100 pcs Communicatio...

Page 26: ...26...

Page 27: ...100 I__ 02 BD Controller 101N07xx Series 24 V DC with Tool4Cool LabEdition software and Danfoss One Wire LIN gateway Quick Start Guide DEHC PS 100 J__ 02 Danfoss One Wire LIN Gateway 105N9501 Instruct...

Page 28: ...er its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed...