Instruction CF-RU Repeater Unit
VI.UH.N6.1T
Produced by Danfoss Floor Heating Hydronics 08.2010
7
GB
5. Uninstallation
Factory reset - fig. 4
• Disconnect the Repeater Unit from the power supply.
• Release the front cover – see fig. 3.
• Press and hold down the push button .
• Meanwhile plug in the power supply again.
• Release the push button when the LED goes ON and OFF.
6. Specifications
Cable lenght (power supply)
3m
Transmission frequency
868.42MHz
Transmission range in buildings (up to)
30m
Number of Repeater Units in a chain (up to)
3
Transmission power
<1mW
Supply voltage
230 V AC / 4.5V
Ambient temperature
0-50°C
IP class
21
7. Troubleshooting
Error indication
Possible Causes
The LED flashes 5 times
Installation/Link Test is unsatisfactory