Part#:212-0042 7
July 31, 2019
*
Factory
Default
Program MODE 2 - Using Table 2
1) Enter setup mode Enter by holding SW7+SW8 (see Figure 3) and wait for the 2 beeps
2) Select the program feature you wish to change or set from table 2
3) Change the status (OFF/ON) of SW9 to SW16 to activate the desired function in Table 2.
4) To save the configuration; press and hold SW9 (STBY/PA) until the long beep, this confirms the pro-
gram is saved.
SW
OFF
ON
9
SW14 AIR HORN
*
SW14 MANUAL
10
DO NOT CHANGE
*
11
ARROWSTICK ENABLED and controlled by
SW16
ARROWSTICK DISABLED
*
12
STANDARD ARROW CTRL (CODE 3)
*
911 ARROW CONTROL
13
SW8 SOLID
*
SW8 MOMENTARY
14
SW15 (Output 12) ACTIVE W/O IGNITION
*
SW15 (Output 12) ACTIVE W/I INGITION
15
SEE TABLE 3
*
16
SEE TABLE 3
*
Figure 3 - Program Mode 2
Table 2 - Program Mode 2 - Function setting by SW9 to SW16
SETTING
SW15
SW16
OUTPUT 4 TIMER FUNCTION
1
OFF
OFF
OUTPUT 12 SOLID
2
OFF
ON
OUTPUT 12 TIMER (30 SEC)
3
ON
OFF
OUTPUT 12 MOMENTARY
4
ON
ON
OUTPUT 12 TIMER (9 SEC)
Table 3 - Timer Output for SW15 output 12
BOTTOM ROW SW9 TO SW16 are FUNCTION set switches, these are used after
entering “PROGRAM MODE”