C. Threading the Film

C. Threading the Film
Remove the feed tray and the heatguard. Thread the 

¿

 lm as 

shown in the 

¿

 gure on the right. Pull the 

¿

 lm around the idler 

rollers as shown. Do not mistake the reinforcing bar for the 

Do not mistake the reinforcing bar for the 

idler roller

idler roller. Make sure the glossy and dull sides of the 

¿

 lm 

Make sure the glossy and dull sides of the 

¿

 lm 

are as indicated in the diagram

are as indicated in the diagram. Position the threading board 
provided. 

Turn power and keyswitch to on.

Start the motor by pressing the “Fwd” but-
ton. Feed the threading board and 

¿

 lm  in 

between the heat shoes. This will pull the 

¿

 lm through the rollers until it comes out 

the back of the laminator.

Slide the top and bottom 

¿

 lm rolls from side 

to side on the mandrels so that the 

¿

 lm is 

perfectly aligned top and bottom (Note: 
overlap will cause the 

¿

 lm to deposit resi-

due on the heat shoes and rollers, so this 
procedure is critical). Replace feed tray 
and heat guard.

7

DULL SID

E

SH I NY SID

E

DUL L  SI D

E

S H I N Y  S I

DE

Laminator.com

www.laminator.com

Summary of Contents for Minikote EZ G3

Page 1: ...OWNERS MANUAL Minikote EZ 652792 Laminator com www laminator com ...

Page 2: ... A Control Panel 5 B Loading Film 1 Mandrel 6 C Threading Film 7 D Laminating 8 E Supply Roll Tension Adjustment 8 9 V Maintaining the Minikote EZ A Care and Cleaning 9 B Speci c Troubleshooting Guide 10 C Removing a Wrap Around 10 11 Appendix A Replacing the Hand Held Cutter Blades 11 Exploded Diagram 12 Warranty 13 Laminator com www laminator com ...

Page 3: ...SPECIFICATIONS Height 15 Width 34 Depth with feed tray 20 Net Weight 66 lbs Shipping Weight 72 lbs Capacity 27 Electrical 120V AC 60Hz 1400w 1 Laminator com www laminator com ...

Page 4: ... of air through its ventilation openings This unit should be situated away from heat and air ventilation systems such as radiators heat regis ters stoves etc This unit should only be connected to a power supply outlet of the voltage amperage and frequency marked on its serial tag For 120 volt machines the socket outlet shall be installed near the equipment and be easily accessible The power supply...

Page 5: ...iently located on the Supply Mandrels K on the right side panel for easy access A Control Panel G is located on the Left Housing E with a Motor Stop Reverse switch B and a Heat On Off Switch A The Feedtray H and Feed Guide I provide a smooth durable paper path and the Heat Guard F protects hands from hot surfaces inside TeÀon coated Heat Shoes J minimize friction The Cutter D cuts and trims your l...

Page 6: ...GENERAL DIAGRAMS 4 D E J G H K L I F N M Laminator com www laminator com ...

Page 7: ...00 lm thicknesses III Operating III Operating A Control Panel A Control Panel The control panel is located on the left side of the laminator This panel is used to control the various machine functions listed below Heat A M N Heat A M N The temperature can be turned either on or off using the the heat switch A which is located on the control panel The heat can be controlled manually using the heat ...

Page 8: ...f the laminator The slot end ts into the tension adjuster on the right side Slide the lm roll onto the mandrel by rotat ing the mandrel in the opposite direction of the gripper points leaving equal lengths of mandrel sticking out of each end The lm roll will slide over the gripper which will keep the roll from turning on the shaft Load the mandrel on the laminator by in serting the slot end of the...

Page 9: ...ated in the diagram Position the threading board provided Turn power and keyswitch to on Start the motor by pressing the Fwd but ton Feed the threading board and lm in between the heat shoes This will pull the lm through the rollers until it comes out the back of the laminator Slide the top and bottom lm rolls from side to side on the mandrels so that the lm is perfectly aligned top and bottom Not...

Page 10: ...f lm to clear the rollers at the end of your document and turn the motor switch to stop Using the hand held cut ter hold tension on the laminated document and slice through the lm to release the document Multiple documents can be run successfully if desired and cut at a later time E Supply Roll Tension Adjustment L E Supply Roll Tension Adjustment L Top and bottom supply rolls should have about th...

Page 11: ...g A Care and Cleaning In the normal course of operating the Minikote EZ dirt and adhesive will accumulate on the heat shoes and rubber rollers Laminating produces static electricity which attracts airborne dust and dirt Regular inspection and cleaning will assure that this does not become a problem Never Never use hard sharp or abrasive items to clean the heat shoes The shoes are coated with a non...

Page 12: ...r rollers several times follow this procedure 10 I n c r e a s e H e a t D e c r e a s e H e a t W o r n D i r t y O r D a m a g e d R o l l e r s I n c r e a s e T e n s i o n O n S u p p l y R o l l s D i r t y H e a t S h o e s M o i s t O r C o a t e d P r o d u c t D e c r e a s e T e n s i o n O n S u p p l y R o l l s C h e c k T h r e a d i n g D i a g r a m Wrinkles on Film side to side W...

Page 13: ...and rethread the lm Appendix A Appendix A Replacing the hand held Cutter Blades Replacing the hand held Cutter Blades The hand held cutter blade can be replaced by removing the small screw on the back of the cutter then removing the cutter back Caution The cutter blade is extremely Caution The cutter blade is extremely sharp Please handle carefully and dis sharp Please handle carefully and dis pos...

Page 14: ...EXPLODED VIEW 12 L E F T S I D E P AN E L E L E CT R O N I CS E X P L O D E D V I E W Laminator com www laminator com ...

Page 15: ...n of consequential damages so the above limitation may not apply to you There are no consumer serviceable parts in the Minikote EZ Laminator If you require service under this Warranty contact your dealer to obtain Return Authorization RA pack the product in its original packag ing or request the same from Technical Service when requesting the RA and include a description of the malfunction and pro...