2.2. Connections
The cabinets are fitted with a pair of NL4 connectors and a two
pole screw terminal block (ST). All four pins of both NL4
connectors are wired in parallel. The cabinets use the pin
assignments 1+/1–. Pins 2+/2– are designated to active
subwoofers.
Cabinets with the weather resistant option (WR) are equipped with
a fixed input cable (PG type, H07-RN-F, 2 x 2.5 mm
2
(AWG 13),
standard length 5.5 m (18 ft).
Pin equivalents of the applicable connector options are listed in the
table below.
NL4
1+
1–
2+
2–
ST
+
–
n.a.
n.a.
PG
Brown (+)
Blue (–)
n.a.
n.a.
Fixed cable connection
The Yi8 and Yi12 loudspeakers are each supplied with a cover
plate
[1] and a rubber grommet feed through [2]. For indoor
operation, these items can be used to hide the connector panel, if
required. For unprotected outdoor operation, the connector panel
must be covered, i.e. both items must be used to achieve an IP
degree of protection of IP34.
To install the fixed cable connection, proceed as follows:
Tools required: Philips screw driver (#PH2).
1. Remove the knockout opening in the cover plate
[1] and
attach the rubber grommet
[2] correspondingly.
2. Insert the connection cable through the rubber grommet.
3. Undo the four screws of the connector panel.
4. Connect the cable wires to the screw terminal.
Þ
Observe the correct polarity!
5. Push the cover plate towards the connector panel until it fits
into place.
6. Finally fix the cover plate together with the connector panel
using all screws.
passive
crossover
Connector wiring
Cover plate and rubber grommet
Step 1
d&b Yi8/Yi12 Manual 1.1 en