background image

Connections

Fig. 3: Connector wiring

The E12 cabinet is fitted with a pair of EP5 connectors. All five pins of
both connectors are wired in parallel. The E12 uses the pin assignments
1/2. Pins 3/4 and 5 are designated to active subwoofers, where pin 5
is used for SenseDrive (only available when using a D12 amplifier and
5-wire cabling). Using the male connector as the input, the female
connector allows for direct connection to additional loudspeakers.

The E12 can be supplied with NL4 connectors as an option. 

Pin equivalents of EP5 and NL4 connectors and the fixed cable option
are listed in the table below.

EP5

1

2

3

4

5

NL4

1+

1–

2+

2–

n.a.

Fixed cable (PG)

Brown (+)

Blue (–)

Operation with D6 or D12

Select the controller setups E12 or E12-D.

Within the D12 amplifier they are available in "Dual Channel" and
"Mix TOP/SUB" mode. For combinations with active subwoofers fed by
a single 4/5-wire cable "Mix TOP/SUB" mode must be selected.

D6 and D12 provide the additional setups E12-X and E12-DX to be
selected when E12 or E12-D cabinets are used in combination with
passive E15X-SUB loudspeakers on the same channel. They provide a
dedicated correction for the combined frequency response of these
systems.

Selecting the E12 (E12-D) setup enables up to a total of two E12 (E12-
D) loudspeakers to be driven by the respective D12 or D6 channel.

Selecting the E12-X (E12-DX) setup enables a combination of one E12
(E12-D) and one E15X-SUB to be driven by the respective D12 or D6
channel.

In applications with low continuous levels and low ambient
temperatures up to three cabinets can be connected to a D12 channel.

Controller settings

For acoustic adjustment the functions CUT, HFA and CPL can be
selected.

CUT circuit

Set to CUT, the E12 low frequency level is reduced. The E12 is now
configured for use with E15X-SUB in active mode or other d&b active
subwoofers.

E12, E12-D Manual

(1.2 EN)    

Page 5 of 10

Summary of Contents for E12

Page 1: ...E12 E12 D Manual 1 2 EN ...

Page 2: ...tion E12 E12 D Manual Version 1 2 EN 10 2008 D2031 EN 01 Copyright 2008 by d b audiotechnik GmbH all rights reserved Keep this manual with the product or in a safe place so that it is available for future reference When reselling this product hand over this manual to the new customer If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals ...

Page 3: ...accessories as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories ...

Page 4: ...thout tools to modify the horn orientation The cabinets incorporate a pair of handles a recessed pole mount socket and six M10 threaded inserts to connect to different rigging accessories like Z5352 E12 Flying bracket Z5354 E8 E12 Flying adapter Z5020 Flying adapter 02 Z5025 Flying adapter 03 or Z5353 E12 Horizontal bracket An additional M10 thread in the rear panel can be used to connect a safety...

Page 5: ...active subwoofers fed by a single 4 5 wire cable Mix TOP SUB mode must be selected D6 and D12 provide the additional setups E12 X and E12 DX to be selected when E12 or E12 D cabinets are used in combination with passive E15X SUB loudspeakers on the same channel They provide a dedicated correction for the combined frequency response of these systems Selecting the E12 E12 D setup enables up to a tot...

Page 6: ...n building closely coupled arrays or when the cabinet is used as a stage monitor CPL begins gradually at 1 kHz with maximum attenuation below 250 Hz providing a balanced frequency response when E12 cabinets are used in arrays of two or more The function of the CPL circuit is shown in the diagram opposite and can be set in dB attenuation values between 9 and 0 or a positive CPL value which creates ...

Page 7: ... standard setup Fig 8 Isobar diagram E12 horizontal horizontal setup with the horn rotated Fig 9 Isobar diagram E12 vertical horizontal setup with the horn rotated Fig 10 Isobar diagram E12 D horizontal standard setup Fig 11 Isobar diagram E12 D vertical standard setup Fig 12 Isobar diagram E12 D horizontal horizontal setup with the horn rotated Fig 13 Isobar diagram E12 D vertical horizontal setu...

Page 8: ... grill while the cabinet is mounted or flown above the ground Tools required screw driver or an appropriate coin Undo the quick locks at the top and bottom of the front grill and remove the grill Pick the horn at its outer edges and turn it until it snaps into the desired orientation Relocate and fix the front grill CAUTION Make sure both quick locks of the front grill are locked correctly before ...

Page 9: ...tor of 4 Input level 100 dB SPL 1 m 17 dBu E12 E12 D loudspeakers Nominal impedance 8 ohms Power handling capacity RMS peak 10 ms 300 1600 W Nominal dispersion angle hor x vert 80 x 50 110 x 50 Components 12 driver with neodymium magnet coaxial 1 3 exit compression driver with 3 coil and rotatable CD horn Passive crossover network Connections 2 x EP5 Optional and SC option 2 x NL4 WR option Fixed ...

Page 10: ...uding all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respective national regulations or contra...

Reviews: