background image

Technical specifications

Ci7-TOP system data

Frequency response (–5 dB)...................................................................68 Hz – 18 kHz
Max. sound pressure (1 m, free field) with D12................................................138 dB
Max. sound pressure (1 m, free field) with D6...................................................134 dB
Max. sound pressure (1 m, free field) with P1200A.........................................136 dB

(SPLmax peak, pink noise test signal with crest factor of 4) 

Input level (100 dB SPL / 1 m).............................................................................–19 dBu

Ci7-TOP loudspeaker

Nominal impedance..................................................................................................8 ohms
Power handling capacity (RMS / peak 10 ms).......................................200 / 800 W
Nominal dispersion angle (hor. x vert.)...........................................................75° x 40°
Components..........................................................................................................15” driver
.........................................................................................................1.5” compression driver
....................................................................................................passive crossover network
Connections...............................................................................................................1 x NL4
...........................................optional fixed cable (H-07-RN-F 2 x 2.5 qmm/AWG 13)
Pin assignments.................................................................................................NL4: 1+/1–
.............................................................................................Fixed cable: Brown + / Blue –
Weight............................................................................................................50 kg (110 lb)

-5

0

5

10

-10

-15

-20

-25

-30

20

100

1k

10k

20k

Fig. 6: Ci7-TOP frequency response, standard, CUT and HFA switch
settings

500

 [19.68"]

580  [22.83"]

58

0

 [22

.8

3"]

6

2

0

 [

2

4

.4

1"]

273 [10.75"]

M16

240  [9.45"]

M12

M16

Fig. 7: Ci7-TOP cabinet dimensions in mm [inch]

Ci7-TOP Manual

(2.1 EN)    

Page 7 of 8

Summary of Contents for Ci7-TOP

Page 1: ...Ci7 TOP Manual 2 1 EN ...

Page 2: ... Information Ci7 TOP Manual Version 2 1 EN 02 2008 D2052 E 02 Copyright 2008 by d b audiotechnik GmbH all rights reserved Keep this manual with the product or in a safe place so that it is available for future reference When reselling this product hand over this manual to the new customer If you supply d b products please draw the attention of your customers to this manual Enclose the relevant man...

Page 3: ... accessories as detailed in our specific Mounting instructions or in our Flying system and rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories...

Page 4: ... threaded inserts are used the Ci7 TOP cabinet may be deployed for either 75 x 40 or 40 x 75 coverage NOTICE Only operate Ci7 TOP loudspeakers with a correctly configured d b amplifier otherwise there is a risk of damaging the loudspeaker components Weather resistant WR option NOTICE The WR option enables operation of loudspeakers in changing ambient conditions however it is not intended to enable...

Page 5: ...the d b active subwoofers HFA circuit 5 0 5 10 10 15 20 25 30 20 100 1k 10k 20k Fig 2 Frequency response correction of HFA circuit In HFA mode High Frequency Attenuation the HF response of the system is rolled off The HFA circuit provides a natural balanced frequency response when a unit is placed close to listeners in near field or delay use High frequency attenuation begins gradually at 1 kHz dr...

Page 6: ...inets can be driven by each P1200A power amplifier channel fitted with a C7 TOP controller module Fitting one C7 TOP and one subwoofer controller module allows a single mainframe to drive two Ci7 TOP and two active subwoofer cabinets The CUT and HFA settings are available The characteristics of the CUT and HFA settings are explained in the previous section Operation with D6 or D12 Controller setti...

Page 7: ... ohms Power handling capacity RMS peak 10 ms 200 800 W Nominal dispersion angle hor x vert 75 x 40 Components 15 driver 1 5 compression driver passive crossover network Connections 1 x NL4 optional fixed cable H 07 RN F 2 x 2 5 qmm AWG 13 Pin assignments NL4 1 1 Fixed cable Brown Blue Weight 50 kg 110 lb 5 0 5 10 10 15 20 25 30 20 100 1k 10k 20k Fig 6 Ci7 TOP frequency response standard CUT and HF...

Page 8: ...pplicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respective national regulations or contractual agree...

Reviews: