Connections

Ci7-TOP cabinets are fitted with a single NL4 connector and are driven
using pins 1+/1–.

Installation loudspeakers with the weather resistant option are supplied
with a fixed cable (PG). 

Cable type:

H-07-RN-F 2 x 2.5 mm2/AWG 13 

Standard length: 5.5 m (18 ft) 

Pin equivalents of NL4 connectors and fixed cable option (PG) are listed
in the table below.

NL4

1+

1–

2+

2–

PG

Brown (+)

Blue (–)

Operation with D6 or D12

Select the controller setup C7-TOP.

Within the D12 amplifier this is available in "Dual Channel" and "Mix
TOP/SUB" mode.

Up to a total of two Ci7-TOP loudspeakers can be driven by each D6
or D12 amplifier channel.

In applications with low continuous levels and low ambient temperatures
up to three cabinets can be connected to a D12 channel.

Controller settings

For acoustic adjustment the functions CUT, HFA and CPL can be
selected.

CUT

Set to CUT, a high pass filter with a 130 Hz cut off frequency is inserted
in the controller signal path. The Ci7-TOP is now configured for use with
the d&b active subwoofers.

HFA circuit

-5

0

5

10

-10

-15

-20

-25

-30

20

100

1k

10k

20k

Fig. 2: Frequency response correction of
HFA circuit

In HFA mode (High Frequency Attenuation), the HF response of the
system is rolled off. The HFA circuit provides a natural, balanced
frequency response when a unit is placed close to listeners in near field
or delay use.

High frequency attenuation begins gradually at 1 kHz, dropping by
approximately 3 dB at 10 kHz. This roll-off mimics the decline in
frequency response experienced when listening to a system from a
distance in a typically reverberant room or auditorium.

CPL circuit

Fig. 3: Frequency response correction of
CPL circuit

The CPL (Coupling) circuit compensates for coupling effects between the
cabinets when building closely coupled arrays. CPL begins gradually at
1 kHz, with maximum attenuation below 250 Hz, providing a balanced
frequency response when cabinets are used in arrays of two or more.
The function of the CPL circuit is shown in the diagram opposite and can
be set in dB attenuation values between –9 and 0, or a positive CPL
value which creates an adjustable low frequency boost around 65 Hz (0
to +5 dB).

Ci7-TOP Manual

(2.1 EN)    

Page 5 of 8

Summary of Contents for Ci7-TOP

Page 1: ...Ci7 TOP Manual 2 1 EN ...

Page 2: ... Information Ci7 TOP Manual Version 2 1 EN 02 2008 D2052 E 02 Copyright 2008 by d b audiotechnik GmbH all rights reserved Keep this manual with the product or in a safe place so that it is available for future reference When reselling this product hand over this manual to the new customer If you supply d b products please draw the attention of your customers to this manual Enclose the relevant man...

Page 3: ... accessories as detailed in our specific Mounting instructions or in our Flying system and rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories...

Page 4: ... threaded inserts are used the Ci7 TOP cabinet may be deployed for either 75 x 40 or 40 x 75 coverage NOTICE Only operate Ci7 TOP loudspeakers with a correctly configured d b amplifier otherwise there is a risk of damaging the loudspeaker components Weather resistant WR option NOTICE The WR option enables operation of loudspeakers in changing ambient conditions however it is not intended to enable...

Page 5: ...the d b active subwoofers HFA circuit 5 0 5 10 10 15 20 25 30 20 100 1k 10k 20k Fig 2 Frequency response correction of HFA circuit In HFA mode High Frequency Attenuation the HF response of the system is rolled off The HFA circuit provides a natural balanced frequency response when a unit is placed close to listeners in near field or delay use High frequency attenuation begins gradually at 1 kHz dr...

Page 6: ...inets can be driven by each P1200A power amplifier channel fitted with a C7 TOP controller module Fitting one C7 TOP and one subwoofer controller module allows a single mainframe to drive two Ci7 TOP and two active subwoofer cabinets The CUT and HFA settings are available The characteristics of the CUT and HFA settings are explained in the previous section Operation with D6 or D12 Controller setti...

Page 7: ... ohms Power handling capacity RMS peak 10 ms 200 800 W Nominal dispersion angle hor x vert 75 x 40 Components 15 driver 1 5 compression driver passive crossover network Connections 1 x NL4 optional fixed cable H 07 RN F 2 x 2 5 qmm AWG 13 Pin assignments NL4 1 1 Fixed cable Brown Blue Weight 50 kg 110 lb 5 0 5 10 10 15 20 25 30 20 100 1k 10k 20k Fig 6 Ci7 TOP frequency response standard CUT and HF...

Page 8: ...pplicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respective national regulations or contractual agree...