d&b audiotechnik 5D Startup Manual Download Page 9

Technical specifications

Controls and indicators
Controls

POWER

Mains power switch (rear panel)

RESET

Recessed push-button (rear panel)

Indicators

POWER

Power indicator (green)

Data

Data stream indicator (yellow)

Mute A/B/C/D

Channel mute indicator (red)

Channel/Device error indication (red)

ISP A/B/C/D

Input Signal Present indicator (green)

GR A/B/C/D

Gain Reduction indicator (yellow)

OVL/Error A/B/C/D

Overload/Error indicator (red)

 

Fan noise emission

Rack mounted, measured on axis, 1 m (3.3 ft) to front panel, A-weighting.
Max. RPM

42 dB(A)

Ambient temperature 23 °C/73.4 °F

Dimensions and weight

Height x Width x Depth

*

1 RU x 9.5" x 405 mm (16")

*with rack ears 435 mm (17.1")

Weight

4.6 kg/10 lb

5D enclosure dimensions in mm [inch]

*Audio power output – Measurement references:
All data is valid for 23 °C (73.4 °F) ambient temperature and

230 V AC/50 Hz mains supply.
The power rating of noise signals is defined as the maximum of the

instantaneous output power divided by a factor of two.

 

The power of burst signals refers to the power during the "on"

period.
The duration of the peak output of a sinewave signal is defined at

a drop of 0.5 dB/10% relative to the maximum output power.

EIA-426B noise
Crest factor

Load

Power rating

Power average

12 dB

4 Ohm
8 Ohm

4 x 600 W
4 x 600 W

4 x 75 W
4 x 75 W

9 dB

4 Ohm
8 Ohm

4 x 350 W
4 x 350 W

4 x 87.5 W
4 x 87.5 W

6 dB

4 Ohm
8 Ohm

4 x 175 W
4 x 175 W

4 x 87.5 W
4 x 87.5 W

1 kHz burst
On/off time

Load

Power single channel

Power all channels

20 ms/0 dB
480 ms/–20 dB

4 Ohm
8 Ohm

1 x 760 W
1 x 600 W

4 x 170 W
4 x 185 W

200 ms/0 dB
600 ms/–20 dB

4 Ohm
8 Ohm

1 x 600 W
1 x 585 W

4 x 145 W
4 x 160 W

1 kHz sine wave
Channels used

Load

Max. output power

Duration of max. output

1

4 Ohm
8 Ohm

1 x 600 W
1 x 600 W

1200 ms
1600 ms

4

4 Ohm
8 Ohm

4 x 600 W
4 x 600 W

7 ms
7 ms

 

d&b 5D Start-up manual 1.1 en

- preliminary -

9

Summary of Contents for 5D

Page 1: ... preliminary xD5D Start up manual 1 1 en ...

Page 2: ... the d b website for the latest version of this document When reselling this product hand over this document to the new owner If you supply d b products please draw the attention of your customers to this document Enclose the relevant documents with the systems If you require additional documents for this purpose you can order them from d b d b audiotechnik GmbH Co KG Eugen Adolff Str 134 D 71522 ...

Page 3: ...d upon or pinched particularly at the plugs and the point where it exits from the apparatus 8 The unit is intended for use in a 19 rack Follow the mounting instructions When a rack on wheels is used exercise caution when moving the loaded rack to avoid injury from tipping over 9 Unplug this apparatus during lightning storms or when unused for long periods of time 10 Never connect an output pin to ...

Page 4: ... connection 15 5 2 2 Analog audio input link connectors 16 5 2 3 ETH1 ETH2 Dante 16 5 2 4 OUTPUTS 17 5 2 5 GPI DC Hardware description 18 5 2 6 FAULT 18 5 3 Controls and indicators 19 5 3 1 Mains power switch 19 5 3 2 RESET System reset 19 5 3 3 Status indicators LEDs 20 6 Service Maintenance and care 21 6 1 Service 21 6 2 Maintenance and care 21 7 Manufacturer s declarations 22 7 1 Declaration of...

Page 5: ...lity and high complexity of the device this manual covers the basic safety instructions as well as the vital technical specifications and instructions for startup A full version of this manual Þ Reference manual with comprehensive information is available for download on the related product page of the d b website at www dbaudio com 1 2 Loudspeaker types The maximum number of cabinets driven by ea...

Page 6: ...UTPUTS connector sockets Connector type Euroblock 5 08 mm 4 1 3 pin Euroblock female Intended for the FAULT connector socket Connector type Euroblock 3 5 mm D2766 EN 01 d b 5D Start up manual Mains plug types and associated standards Z2611 001 3 pin Schuko CEE 7 7 Z2611 011 3 pin UK BS 1363A Z2611 021 3 pin U S NEMA 5 15P Z2611 041 3 pin Japan Z2611 051 3 pin South Korea KS C8305 Z2611 081 3 pin A...

Page 7: ...ions is included with the device Please also refer to Þ Chapter 5 1 Rack mounting and cooling on page 13 Pos Qty d b Code Description 5 2 Rack ears 6 1 19 Adapter Bridge 7 4 Dual connector plates 8 10 Countersunk torx TX10 screws M3 x 5 Tuflock d b 5D Start up manual 1 1 en preliminary 7 ...

Page 8: ... unweighted 330 µVRMS 108 dB Analog input A weighting 240 µVRMS 111 dB Dante input unweighted 240 µVRMS 111 dB Dante input A weighting 180 µVRMS 113 dB THD N Crosstalk THD N unweighted 20 20 kHz 4x 75 W 8 ohms 60 dB 0 1 4x 75 W 4 ohms 50 dB 0 1 Crosstalk 20 20 kHz 50 dBr 4x 75 W into 4 Ω Analog inputs link INPUT A1 A4 3 pin Euroblock male Pin assignment GND neg pos Input impedance 15 kΩ electronic...

Page 9: ...30 VAC 50 Hz mains supply The power rating of noise signals is defined as the maximum of the instantaneous output power divided by a factor of two The power of burst signals refers to the power during the on period The duration of the peak output of a sinewave signal is defined at a drop of 0 5 dB 10 relative to the maximum output power EIA 426B noise Crest factor Load Power rating Power average 1...

Page 10: ...s 230 VAC 50 Hz 0 5 Ω Source impedance all channels driven State Load ohms Mains current A RMS Power factor Input power W Output power W Power loss W BTU hr kCal hr Standby 0 1 0 17 4 4 14 3 AutoWakeup 0 1 0 19 5 5 17 4 Idling 0 4 0 6 49 49 167 42 Noise CF 12 dB 8 ohms 4 ohms 1 9 2 1 0 92 0 92 410 450 300 300 110 150 375 512 95 129 Noise CF 9 dB 8 ohms 4 ohms 2 2 2 4 0 93 0 94 475 520 350 350 125 ...

Page 11: ... 4 7 0 97 0 97 490 540 350 350 140 190 478 648 120 163 Sinus max 1 s 8 ohms 4 ohms 10 2 10 4 100 VAC 60 Hz 0 2 Ω Source impedance all channels driven State Load ohms Mains current A RMS Power factor Input power W Output power W Power loss W BTU hr kCal hr Standby 0 1 0 42 4 4 14 3 AutoWakeup 0 1 0 46 5 5 17 4 Idling 0 6 0 77 48 48 164 41 Noise CF 12 dB 8 ohms 4 ohms 4 5 5 0 0 95 0 95 430 470 300 3...

Page 12: ... Chapter 5 2 3 ETH1 ETH2 Dante on page 16 5 DC Out GPI connector Refer to Þ Chapter 5 2 5 GPI DC Hardware description on page 18 6 FAULT connector Refer to Þ Chapter 5 2 6 FAULT on page 18 4 2 Controls and indicators User interface 9 Status indicators Refer to Þ Chapter 5 3 3 Status indicators LEDs on page 20 7 POWER Main power switch Refer to Þ Chapter 5 3 1 Mains power switch on page 19 8 RESET ...

Page 13: ...devices at the top bottom front and rear 2 On one device don t matter which attach the dual connector plates 7 Ensure the countersinks faces to the top 3 Join the devices together 4 Redo the remaining screws of the second device at the top bottom front and rear Rack mounting NOTICE When mounting into 19 equipment racks or cabinets it is strongly recommend that you Always fix the device at its fron...

Page 14: ...ease ensure that adequate cool airflow is provided Do not block or cover the front panel air intake or the vents on the rear panel If the amplifiers are installed in sealed cabinets e g in fixed installations use additional fan modules with filters that can be easily replaced without opening the sealed cabinets Do not rack up the amplifiers together with other devices producing additional heat wit...

Page 15: ...y time to disconnect the device in case of malfunction or danger If the mains plug is not readily accessible due to mounting in a 19 rack or equipment cabinet then the mains plug for the entire rack or cabinet must be readily accessible Do not connect or disconnect the mains plug under load Before connecting the device to mains voltage check that the mains voltage and frequency correspond to the s...

Page 16: ...tly when the speed is 1 Gbits A dual Ethernet port with a built in 2 port Ethernet switch 1 Gbits 100 Mbits peer to peer is provided enabling standard remote control via the d b Remote network OCA AES70 and SNMP IP address Auto DHCP LL or Manual as well as digital audio networking on either of the connector sockets It allows either daisy chain or star wiring topology How ever star wiring topology ...

Page 17: ...2 AWG 13 Ensure all contact screws are properly tightened Rated torque settings max 0 5 N m Screw driver size Phillips PH1 0 6 x 3 5 mm The amplifier is equipped with two Euroblock connector sockets female one for each pair of amplifier output channels A B C D All pins of both output connectors are hardwired and permanently driven using the following pin assignment OUTPUTS A B C D Amp A B C D pos ...

Page 18: ...GPIs 1 4 DC DC 12 VDC 50 mA Note A detailed description of how to configure the GPIs and assign the available software objects Function correspondingly is given in the 5D Reference manual which can be downloaded from the related product page at www dbaudio com 5 2 6 FAULT An additional 3 pin Euroblock fault contact 7 is provided allowing a general device error to be remotely indicated Note The ass...

Page 19: ...rform a system reset proceed as follows Note All device preferences will be set to factory defaults except for the network and fixed device settings 1 Switch off 2 Press and hold the RESET button using an appropriate pen 3 While holding the RESET button pressed repower the device All LEDs will illuminate red for 1 second while the POWER LED stays illuminating in green 4 Release the RESET button an...

Page 20: ...g flashing patterns Channel error Single flash of the corresponding Channel mute LED Device Error Double flash of all Channel mute LEDs Signal LED Multi color LED indicates three states Off No signal present Green ISP Input Signal Present Illuminates when the analog input signal exceeds 30 dBu or when the Dante input signal exceeds 57 dBFS Yellow GR Gain Reduction Illuminates when one limiter redu...

Page 21: ...the device under any circumstances Refer servicing only to qualified service personnel authorized by d b audiotechnik In particular if objects or liquids have entered the device the device does not operate normally the device was dropped or the housing is damaged 6 2 Maintenance and care During normal operation the amplifier provides maintenance free service Due to the cooling concept no dust filt...

Page 22: ... from d b or downloaded from the d b website at www dbaudio com 7 2 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respective national regulations or contractual agreements If there are any further questions concerning the disposal of this product p...

Page 23: ......

Page 24: ...D2766 EN 01 05 2022 d b audiotechnik GmbH Co KG www dbaudio com ...

Reviews: