background image

 

2.4. Technical specifications

27S-SUB/27A-SUB system data

Frequency response (–5 dB standard) 

40 Hz - 140 Hz

Frequency response (–5 dB 100 Hz mode)

40 Hz - 100 Hz

Max. sound pressure (single cabinet, 1 m, free field)
with D6

128 dB

with D12

131 dB

(SPLmax peak, pink noise test signal with crest factor of 4)

27S-SUB/27A-SUB loudspeaker

Nominal impedance

6 ohms

Power handling capacity (RMS/peak 10 ms)

500/2000 W

Components

 1 x 15“ driver
 1 x 12“ driver

Connections

 2 x NL4

 1 x screw terminal (ST - up to 4 mm

2

/AWG 11)

Optional fixed cable (PG):

 H07-RN-F, 2 x 2.5 mm

2

 (AWG 13), 5.5 m (18 ft)

Pin assignment

NL4: 2+/2–

Fixed cable (PG): brown + / blue –

Weight

41 kg (90 lb)

Fig. 9: 27A-SUB cabinet dimensions in mm [inch]

Fig. 7: 27S-SUB/27A-SUB frequency response,
standard and 100 Hz mode

Fig. 8: 27S-SUB cabinet dimensions in mm [inch]

 

d&b 27S-SUB/27A-SUB Manual (1.2 EN)

8

Summary of Contents for 27S-SUB

Page 1: ...27S SUB 27A SUB Manual 1 2 EN...

Page 2: ...hts reserved Keep this manual with the product or in a safe place so that it is available for future reference When reselling this product hand over this manual to the new customer d b audiotechnik Gm...

Page 3: ...UB loudspeaker 5 2 1 Product description 5 2 2 Connections 6 2 3 Operation 7 2 3 1 Controller settings 7 2 4 Technical specifications 8 3 Manufacturer s Declarations 9 3 1 EU conformity of loudspeaker...

Page 4: ...s detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of...

Page 5: ...tant according to DIN 18032 3 Cardioid dispersion Cardioid dispersion avoids unwanted energy behind the system and greatly reduces the reverberant field at low frequencies providing highest accuracy i...

Page 6: ...low NL4 1 1 2 2 ST n a n a PG n a n a Brown Blue Fixed cable connection The 27S SUB and 27A SUB loudspeakers are each supplied with a cover plate 1 and a rubber grommet feed through 2 For indoor opera...

Page 7: ...b loudspeakers with a correctly configured d b amplifier otherwise there is a risk of damaging the loudspeaker components Operation with D6 or D12 Select the controller setup 27S SUB for 27S or 27A su...

Page 8: ...oudspeaker Nominal impedance 6 ohms Power handling capacity RMS peak 10 ms 500 2000 W Components 1 x 15 driver 1 x 12 driver Connections 2 x NL4 1 x screw terminal ST up to 4 mm2 AWG 11 Optional fixed...

Page 9: ...ions of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio co...

Page 10: ...D2614 EN 01 12 2011 d b audiotechnik GmbH www dbaudio com...

Reviews: