background image

3

2

Technical certificate 

Technical certificate 

Perform assembling and operation of the greenhouse in strict accordance with 

the manual and operating rules stated in the technical certificate. Please keep 

this technical certificate for further reference.

The "TITAN Arch 196" greenhouse is designed and manufactured in accordance with 
SNiP 2.10.04-85 and generally intended for industrial cultivation of crops at farms 
and peasant holdings.

 Width of the greenhouse is 7.46 m. Area of covered ground depends on the length 

of the greenhouse and for minimal length of 4.2 m is  31.5 m

2

. Height of the installed 

frame  is  3.8  m.  Required  length  of  the  greenhouse  is  provided  by  purchasing  of 
extra  packages  «Insert»  and  adds  2.1  m  to  the  base  length  (table  1).  The  frame  of 
the greenhouse is made of galvanized iron 1 mm thick and is to be assembled with 
screws, nuts and washers. 

The greenhouse is fixed on the ground without foundation by digging special frame 

endings or on a fundament using cleater angles. The type of fixing is determined by 
a buyer. The kit includes everything you need to mount the covering. The greenhouse 
may be completed with covering on buyer’s request.  Number of gates, doors, small 
windows is conformed to a buyer and the complete set of an anteroom is conformed 
to a buyer.

DESCRIPTION

Table 3                               PARAMETERS OF PACKAGES

content

dimensions,mm

weight,no More,kg

FRAME (BASE LENGTH 4.2 M)

1 PACKAGE TITAN Arch 196

3100х200х100

15,0

2 PACKAGE TITAN Arch 196

2800х100х90

28,0

3 PACKAGE TITAN Arch 196

2000х90х100

41,0

4 PACKAGE TITAN Arch 196

2400х90х100

23,0

5 PACKAGE TITAN Arch 196

3100х200х100

15,0

6 PACKAGE TITAN Arch 196

2800х200х100

41,0

7 PACKAGE TITAN Arch 196

2800х200х100

34,0

8 PACKAGE TITAN Arch 196

500х300х100

14,0

9 PACKAGE TITAN Arch 196

2700х100х90

37,0

10 PACKAGE TITAN Arch 196

500х300х100

19,5

EXTRA PACKAGE

INSERT (2.1 M FRAME ELONGATION)

1 PACKAGE INSERT  

(arc elements)

3100х200х100

15,0

2 PACKAGE INSERT  

(power arc straight elements)

2800х100х90

32,0

3 PACKAGE INSERT  

(runners elements)

2100х110х90

43,0

4 PACKAGE INSERT  

(fixtures and component parts for Insert)

200х100х50

2,0

EXTRA PACKAGE

*Completing with one anteroom or more is made at the request of the buyer (purchased separately).

Таблица 1

Таблица 2

COMPLETION WITH PACKAGES, PCS

L

greenhouse 

length, m

N - nu

mber o

f gre

enho

use

 

se

ctio

ns, 

ex

clu

di

ng

FRAME

(basic length 4,2 m)

INSERT

(frame extension for 2,1 m)

EXTRA 

PA

CK

AGE

1 INSE

R

t

 P

ACK

AGE

 

2 INSE

RT 

PA

CK

AGE

3 INSE

RT 

PA

CK

AGE

4 INSE

RT 

PA

CK

AGE

EXTRA 

PA

CK

AGE

4,2

0

1

1

2

2

2

2

2

2

2

1 1

0

0

0

0

0

6,3

1

1

1

1

1

1

8,5

2

2

2

2

2

2

10,6

3

3

3

3

3

3

12,7

4

4

4

4

4

4

14,9

5

5

5

5

5

5

17,0

6

6

6

6

6

6

19,1

7

7

7

7

7

7

21,2

8

8

8

8

8

8

23,4

9

9

9

9

9

9

2,1(N+2)

N

N

N

N

N

COMPLETION WITH TAMBOUR PACKAGES*, PCS

Package name

quantity

dimensions (mm)

max. allowable

Tambour

1

2

700х

1

00х

100

31

Door

1

1

900х

1

00х50

14,2

Tambour packaging

1

200х

1

00х50

1,3

Door sealing

1

500х300х50

1,2

Side wall sealing

1

500х300х50

3,1

Table 1

Table 2

(arc elements)

(power arc straight elements)

(end runners elements)

(end side brace elements)

(arc elements)

(end straight elements and strips)

(end straight elements)

(elements and strips for doors)

(elements and strips for gates)

 

(fixtures, component parts and seal

)

1 TITAN Arch 196 Package

2 TITAN Arch 196 Package

3 TITAN Arch 196 Package

4 TITAN Arch 196 Package

5 TITAN Arch 196 Package

6 TITAN Arch 196 Package

7 TITAN Arch 196 Package

8 TITAN Arch 196 Package

9 TITAN Arch 196 Package

10 TITAN Arch 196 Package

Summary of Contents for TITAN Arch 196

Page 1: ...17 02 2020 for Greenhouse TITAN Arch 196 Manual...

Page 2: ...any length 1 2 f o e l p i t l u m min 4 2 m width 7 46 m height 3 8 m...

Page 3: ...AGE TITAN Arch 196 2800 200 100 41 0 7 PACKAGE TITAN Arch 196 2800 200 100 34 0 8 PACKAGE TITAN Arch 196 500 300 100 14 0 9 PACKAGE TITAN Arch 196 2700 100 90 37 0 10 PACKAGE TITAN Arch 196 500 300 10...

Page 4: ...TITAN Arch 196 5 Bottom arc strainer 2 2 73 5 Top arc strainer 2 2 73 6 Segment strainer 3 2 58 7 Radial strainer 1 4 0 3 7 Radial strainer 2 3 0 54 3 Support 2 0 29 1 Foundation stay brace 2 0 84 3 P...

Page 5: ...78 Bolt 6 14 123 Bolt 6 20 50 Nut 6 251 Bracket 26 17 16 97 Hanger 3 Hinge 1 130 left 2 Straight lug 40 90 2 Pull 80 2 2 Self driving screw 97 Washer 6 91 Table 6 DETAILED PARTS LIST INSERT marking na...

Page 6: ...e as an unheated housing awning warehouse etc it is necessary to control the snowcap to shift the snow down with a wooden or plastic scraper installed on a pole For these variants of operation it is p...

Page 7: ...EXTENDING INSERTS 2 1 1 3 D 2 4 4 5 8 B D E C F Fig 1 General view of the greenhouse with two inserts total length is 8 4 m insert C 2 2 4 5 B 4 5 5 9 5 5 11 4 2 4 4 3 Vocabulary Left side on the lef...

Page 8: ...WITH EXTENDING INSERTS ONE INSERT extends the greenhouse by 2 13 m Number of the inserts for the greenhouse is not limited Fig 1 Fig 1 General view with the anteroom ceiling window door wall side piec...

Page 9: ...arts is carried out in a horizontal plane by connection on side walls of a shape Arcs are connected to each other by nesting at length of the cut with alignment of holes view A bolt 6 14 bolt 6 14 bol...

Page 10: ...t 6 14 bolt 6 14 bolt 6 14 washer 6 washer 6 washer 6 washer 6 Foundation stay braces 1 supports 3 are connected 1 align the side flanges of shapes fig 1 7 view C R 9 10 9 9 9 1 10 10 10 10 10 10 10 1...

Page 11: ...ly joined end runners 2 2 align the side flanges of shapes Runners deviate from the vertical under their own weight and abut against side walls of shapes of arcs 4 until the next operation Installatio...

Page 12: ...washer 6 G 7 6 5 INSTALLATION SEQUENCE General view of the power arc General view of the power arc with the anteroom fig 3 5 fig 3 4 If thegreenhouseisequippedwiththeanteroom install details of the an...

Page 13: ...st and middle runners first STAGE 4 fig 4 1 fig 4 2 2 2 fig 4 2 2 4 STAGE 5 End section installation Inthevariantofinstallation of the greenhouse without a foundation marking of axes is made on the gr...

Page 14: ...and middle runners first using a stepladder Next power arc is joined to the power arc that has already been connected and so on all the arcs are alternatively joined It is recommended to connect the o...

Page 15: ...eet After marking the sheet but prior to cutting it mark the side with the covering layer on each piece of the sheet when the shipping film is removed sheet sides look the same Shipping film shall be...

Page 16: ...2 5 4 4 6 5 7 3 2100 730 1200 2400 2605 5210 2710 950 2500 12000 1100 wall ceiling window CUTTING LIST FOR THE ANTEROOM CUT POLYCARBONATE SHEET IN STRICT ADHERENCE TO FIG 10 3 Honeycomb polycarbonate...

Page 17: ...fig 10 5 Fig 10 5 Using a knife adjust covering pieces to arcs 4 and girder 20 and then install sealing profile in accordance with fig 10 6 self tapping screw 4 2 2 Fig 10 4 end covering end covering...

Page 18: ...from the base package washer 6 from the base package bolt 6 14 washer 6 nut 6 tingle arc base sheet At first install all joint plates and tingles 2940 3 0 0 0 2940 2100 nut 6 ridge shape washer 32 6 b...

Page 19: ...rill holes in part 1 across the holes in bottom draw band top draw band top draw band bottom draw band nut 6 washer 6 bolt 6 60 washer 6 FASTENING OF COVERING bend the ends of the tingle top draw band...

Page 20: ...0 germany dancover com Switzerland 0840 000125 schweiz dancover com France 0975 181 800 france dancover com Austria 0662 626935 austria dancover com Sweden 040 233 262 sverige dancover com Finland 0 9...

Reviews: