background image

CARE AND MAINTENANCE 

Unplug the heater and let it cool down completely.

Keep the heater clean. The outer shell may be cleaned with soft, damp cloth. You may use a
mild detergent if necessary. After cleaning, dry the heater with a soft cloth.

Do not use alcohol, gasoline, abrasive powders, furniture polish, or rough brushes to clean
the heater. This may cause damage or deterioration to the surface of the heater.

Do not immerse the heater in water or allow it to get wet.

Wait till the heater is completely dry before use.

Any type of maintenance or repairs including the replacement of heating tube should only
be carried out by a qualified electrician or by a recommended service center.

For a long time of inactivity, please protect the heater with a fabric cover from rain and dust.

SPECIFICATION 

Wattage: 2000W, 220-240V/50-60Hz 
IP rating: IPX4 
Unit size: 230CM(H)x47CM(D) 
Unit weight:13.00KGS 
Lamp type: Halogen 
Power cord visible length 1.8M 
Radiation area: 10 m

2

 

DISPOSAL 

Waste  electrical  production  should  not  be  disposed  of  with  household  waste.  Please  recycle 
where facilities exist. Check with your local authority or retailer for recycling advice.   

8

Summary of Contents for SENSUI

Page 1: ...for Patio Heater SENSUI Manual 23 09 2021...

Page 2: ...Operating instructions 2 EN DA Index Brugsanvisning 9 1...

Page 3: ...USER S MANUAL ELECTRIC PATIO HEATER For outdoor use only The manual is part of heater it contains important information please keep for future reference EN 2...

Page 4: ...er to avoid a hazard In order to avoid overheating please do not cover the heater The heater must not be located immediately below a socket outlet The heater must be installed at least 1 8 m above the...

Page 5: ...a sauna heater Do not use the heater as a room heater Do not use the heater in place of animal propagating and raising Do not immerse the heater into water for cleaning ASSEMBLY When unpacking the hea...

Page 6: ...30 screw and fully tighten them B Place Deco ring on to the tube STEP TWO Screw middle pole with bottom pole then top pole with middle pole securely While connecting the poles together please insert p...

Page 7: ...n heater head with top pole and screw them together with 2pcs M10x12 screw STEP FOUR While holding the heater lock the cable inside the groove under the base with 2pcs M3 screw STEP FIVE Anchor your h...

Page 8: ...eriod of inactivity please turn off the switch on heater and pull the plug off TURNING THE PATIO HEATER ON AND OFF BY TOUCH SWITCH Insert the plug into a socket Please turn on the rocker switch on hea...

Page 9: ...l the heater is completely dry before use Any type of maintenance or repairs including the replacement of heating tube should only be carried out by a qualified electrician or by a recommended service...

Page 10: ...BRUGERMANUAL ELEKTRISK TERRASSEVARMER Kun til udend rs brug Manualen er en del af produktet og den indeholder vigtige oplysninger som du b r beholde til fremtidig reference DA 9...

Page 11: ...es Terrassevarmeren m ikke v re placeret meget t t p stikkontakt eller str mudtag Terrassevarmeren skal v re mindst 1 8 m over gulvet Brug ikke terrassevarmeren sammen med en timer eller andet fjernbe...

Page 12: ...saunavarmer Brug ikke terrassevarmeren som rumvarmer Brug ikke terrassevarmeren p steder hvor der sker dyreavl og opdr t Neds nk aldrig terrassevarmeren i vand i forbindelse med reng ring MONTAGE N r...

Page 13: ...M6x30 skruer og stram dem helt B Placer Deco ring p r ret TRIN TO Skru den midterste stang sammen med nederste stang og skru derefter den verste stang fast N r du forbinder de tre stykker skal du ind...

Page 14: ...chassis ud for den verste stang og skru dem sammen med 2 stk M10x12 skruer TRIN FIRE Mens du vipper hele terrassevarmeren skal du fastg re ledningen i rillen under foden af apparatet med 2 stk M3 skr...

Page 15: ...en lang periode s skal du slukke p kontakten p terrassevarmeren og tr kke stikket ud T ND OG SLUK FOR TERRASSEVARMEREN P VIPPEKONTAKTEN S t stikket i en stikkontakt T nd for vippekontakten p apparate...

Page 16: ...paratet er helt t r f r du bruger det igen Enhver form for vedligeholdelse eller reparationer herunder udskiftning af varmelegeme b r kun udf res af en kvalificeret elektriker eller af et anbefalet se...

Page 17: ...I For more information please visit www dancovershop com l l l l l l l l l l l Dancover A S Lyngevej 16A N rre Herlev 3400 Hiller d Denmark Head office...

Reviews: