background image

 

 

 

     Fig. 18.3   

 

 

 

 

Fig. 18.4 

 
19.

 At the front and at the back of the greenhouse above the door and back bar holder (No. 9) polycarbonate-

triangle (400x920 mm) covers by its edges side polycarbonate parts and is tightened to the frame with M5-40 
bolts (29), M5 nuts (30), and gaskets (31), and to bar connection angles - with M5-20 bolts (28), M5 nuts 
(30),  and  gaskets  (31).  Then  cut  polycarbonate  near  the  frame  profile  with  a  sharp  knife  or  a  jigsaw,  if 
necessary (Fig. 19.1 

 19.2). 

 

 

 

 

        Fig. 19.1   

 

 

 

        Fig. 19.2 

 
20.

 Apply sealing rubber (36) on the top of channels of side polycarbonate sheets at the top and on the sides 

of the front and the rear parts of the greenhouse, and only after that put side and upper parts of polycarbonate 
(Fig. 20.1 

 20.5).  

 

             

Fig. 20.1 

 

                Fig. 20.2    

 

              Fig. 20.3 

Summary of Contents for GH140040

Page 1: ...12 04 2019 for Greenhouse TITAN Classic 480 Manual...

Page 2: ...m diameter hexagon wrench or an open end wrench A Phillips screwdriver or a battery powered screwdriver A shovel to dig holes A level to measure flatness of a pad Ropes to measure a diagonal Knife to...

Page 3: ...use 2065 2 15 Sides of the foundation for greenhouse extension 2065 2 16 Front and back parts of the foundation 2350 2 2 17 Foundation angles 4 4 18 Foundation connection plates 4 19 Polycarbonate con...

Page 4: ...ts for walls 1050x1485 4 6 Polycarbonate parts for walls 985x1485 4 Side parts for the front and the end 700x1950 4 4 Bottom part of the door 960x1230 1 1 Upper part of the door 960x650 2 2 Triangle a...

Page 5: ...extension Foundation connection plates 18 are used for extension of the foundation if TITAN Classic 480 greenhouse length exceeds 2 12 m or 3 17 m They are fixed from both sides with M5 12 bolts 27 M...

Page 6: ...pth around the whole perimeter of the foundation near fixing points made in the foundation in order to dig in side lower bars No 1 Fig 3 2 12 m 5 holes on the sides 3 17 m 7 holes on the sides 4 12 m...

Page 7: ...g 5 Fig 5 6 Tighten the prepared side lower bars No 1 to the side parts of the assembled foundation with M5 12 bolts 27 and M5 nuts 30 Fig 6 1 6 3 Fig 6 1 Fig 6 2 Fig 6 3 7 Side lower bars No 1 are fi...

Page 8: ...f greenhouse length is 6 12 m cross fastening of the bars is connected as follows 2 12 m No 6 2 07 m No 7 2 07 m No 7 If greenhouse length is 7 17 m cross fastening of the bars is connected as follows...

Page 9: ...er bars No 1 with M5 12 bolts 27 and M5 nuts 30 with the bar connection plates 12 Fig 9 1 9 3 Fig 9 1 Fig 9 2 Fig 9 3 10 Fix the side No 1 and the upper bars No 2 to each other by fixing profiles for...

Page 10: ...M5 12 bolts 27 and M5 nuts 30 Fig 11 1 11 3 Fig 11 1 Fig 11 2 Fig 11 3 12 Tighten the polycarbonate connection angles 19 and the bar connection angles 20 to the side lower bars No 1 the upper bars No...

Page 11: ...No 7 with M5 12 bolts 27 and M5 nuts 30 This action is carried out analogically in the front and at the back Fig 13 1 13 3 Fig 13 1 Fig 13 2 Fig 13 3 14 Tighten the door and back bars No 8 to the door...

Page 12: ...Fig 14 4 15 In the front and at the back of the greenhouse tighten the door and back fixtures No 10 to the door and back bars No 8 with M5 12 bolts 27 and M5 nuts 30 Additionally at the back of the g...

Page 13: ...aw with small teeth a sharp knife if necessary Before installation it is necessary to remove films SAFETY GLOVES ARE NECESSARY TO WEAR WHEN CUTTING SHEETS 17 Upon tightening the frame part of the gree...

Page 14: ...The polycarbonate sheet is tightened to the bar connection angles 19 20 and the polycarbonate connection plates 21 with M5 20 bolts 28 M5 nuts 30 and gaskets 31 The sheet is tightened to the bars of t...

Page 15: ...31 and to bar connection angles with M5 20 bolts 28 M5 nuts 30 and gaskets 31 Then cut polycarbonate near the frame profile with a sharp knife or a jigsaw if necessary Fig 19 1 19 2 Fig 19 1 Fig 19 2...

Page 16: ...s are used to cover the walls Sheet arrangement side view for walls and roof 2 12 m length 1 05 1 05 m Fig 21 1 3 17 m length 1 05 1 05 1 05 Fig 21 2 4 12 m length 1 05 0 985 0 985 1 05 m Fig 21 3 5 1...

Page 17: ......

Page 18: ...th 7th and 9th bars and etc ATTENTION Remove the protective film from the connecting profiles if any Fig 21 6 Fig 21 7 To cover the walls of 4 12 m length TITAN Classic 480 greenhouse 2 sheets of 1050...

Page 19: ...han 2 12 m the H profiles are to be tightened to the bars as follows starting from the front of the greenhouse 3 17 m 3rd and 5th bars 4 12 m 3rd 5th and 7th bars 5 17 m 3rd 5th 7th and 9th bars and e...

Page 20: ...ridge 22 23 Ending F profiles which are fixed by F profile holders 38 are put onto the lower ends of the sheets 39 40 and 41 Fig 22 4 22 7 The holders are tightened to the frame with M5 40 bolts 29 M5...

Page 21: ...ig 23 1 Fig 23 2 Fig 23 4 24 Assembly of the lower and the upper parts of the door Connect all parts supplied in the set of the lower part of the door DOOR No 5 DOOR No 6 DOOR No 3 into a rectangle wi...

Page 22: ...wer 960x1230mm and upper 960x650mm part of the door to the fixed frame parts of the door with M5 40 bolts 29 M5 nuts 30 and gaskets 31 Fig 24 4 NOTE polycarbonate covering of the upper door overhangs...

Page 23: ...in tended for that on the same level with the upper door window handle Make a loop from the door opening holder supplied to you 35 Eyelets of all opening closing doors are made at the handle level wi...

Page 24: ...0 germany dancover com Switzerland 0840 000125 schweiz dancover com France 0975 181 800 france dancover com Austria 0662 626935 austria dancover com Sweden 040 233 262 sverige dancover com Finland 0 9...

Reviews: