background image

Auto

   

Auto

I/O

LED DISPLAY

: Displays the following information

independently; Set Temperature, Ambient Room
Temperature and Auto Timer On/Off settings.

POWER:

Turns unit On / Off.

MODE:

Allows you to scroll through and select the

desired operating mode; Cool 

, Dry 

Fan

Only 

and *Auto 

. The selected mode will

be denoted by the adjacent indicator light.

*‘Auto’ is

a pre-set factory program that automatically defines
the mode (Cool or Dry) and fan speed based on the
set temperature.

FAN SPEED:

Select from four different fan settings;

Low 

Medium , 

High 

and 

Auto

during Cool

and Fan Only mode.

Please note

:

During ‘Dry’

mode the fan speed is automatically defined .

TEMP. /TIMER Control:

Used to increase 

or

decrease 

the Temperature setting in 1°C / °F

increments.and Auto-Timer On/Off settings in 30
min./1hr. increments.

Note :

To change the temperature

scale displayed on the control panel, press both 

simultaneously to alternate the displayed

temperature between Celsius and Fahrenheit.

Auto

5

Mode
Selector

Temp/Timer
Control

Fan
Speed

Power
Button

Energy
Saver

Sleep
Mode

Check
Filter

Key Pad Features

CHECK FILTER

: The adjacent indicator light will

illuminate as a reminder to clean the air conditioner
filter (see page 9)  Once the filter has been cleaned
and replaced, depress the Check Filter button in
order to resume operation.

SLEEP MODE :

When activated, the current set

temperature is gradually increased over a one (1)
hour period then maintained for seven (7) hours.
Once the program is complete, the air conditioner
will resume to it’s previous set temperature (before
sleep mode was activated). This feature is meant to
be used during the night time hours to prevent the
room from getting too cold (while you sleep) and
results in less compressor running time and
reduced energy consumption. Sleep mode may be
cancelled by depressing the Sleep Mode button
while the program is running.

FRESH AIR VENT:

Remains in  Closed 

position

for maximum cooling or Open 

to allow for fresh

air circulation during fan only operation.

ENERGY SAVER:

Automatically cycles the fan on

and off while the compressor is not in use.

Auto
Timer

LED Display

Fresh Air
Vent

AUTO-TIMER:

Used to Initiate the Auto On and/or

Auto Off timer.

While the Air Conditioner is off (Auto-On):
1. Press the Auto-Timer button once and the
adjacent Auto-On indicator light ‘

will illuminate.

2. Use the Temp/Timer control cursors 

to

select a delayed 

On

time of up to 24 hours.

3. Select the  appropriate mode under which you
want the unit to operate (Auto-Cool-Dry-Fan Only)
4. Select the fan speed setting.

display..

While the Air Conditioner is on (Auto-Off);
1. Press the Auto-Timer button twice and the
adjacent Auto-Off indicator light 

will illuminate.

2. Use the Temp/Timer control cursors 

to

select a delayed 

Off

time of up to 24 hours.

display

The Auto On and Auto Off timer can operate during
the same program by defining the Auto-Off
parameters immediately after the Auto On
parameters.
The Auto-Timer may be cancelled at any time by
using the Temp/Timer control cursors 

and

adjusting the timer length to 0.0.

DVAC8036 FINAL OM-.qxp  2006.02.23  17:08  Page 11

5. The time you selected will appear in the LED

3. The time you selected will appear in the LED

Summary of Contents for DVAC10038E

Page 1: ...ÉCAUTION Veuillez lire attentivement les consignes de sécurité et les instructions d utilisation avant l utilisation initiale de ce produit Room Air Conditioner Table of contents 1 Climatiseur de pièce Table of contents 10 Danby Products Limited Guelph Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45839 0669 Version 1B 2 06 DVAC8036 FINAL OM qxp 2006 02 23 17 08 Page 2 ...

Page 2: ...Cooling Speeds Cooling Area Coverage Sq ft Noise Level dB Unit Dimensions Width Depth Height Window Kit Dimensions Minimum Width Minimum Height NOTE Specifications are subject to change without notice for further improvement Model DVAC10038EE 115 60HZ 10 000 1053 9 5 3 3 450 41 8m2 62 DVAC12038EE 115 60HZ 12 000 1265 9 5 3 3 550 51 1m2 62 14 8 16 36 8cm 23 9 16 59 8cm 20 1 4 51 4cm 15 1 2 39 4cm 2...

Page 3: ... Date of Purchase _________________________________________________ Dealer s Name and Address _________________________________________ ________________________________________ Refer to the trouble shooting section of this Use and Care Manual if the unit is not operating correctly If these suggestions do not solve the problem contact an authorized service representative or call Danby TOLL FREE 1 8...

Page 4: ...outlet If you are not sure whether your wall outlet is properly grounded please consult a qualified electrician 5 The wall outlet 3 pin must match the plug 3 pin on the service cord supplied with the unit DO NOT use plug adapters See Table 2 for receptacle and fuse information If it is necessary to use an extension cord to connect your air conditioner use an approved air conditioner extension cord...

Page 5: ...ioner extension cord only available at most local hardware stores G DO NOT install unit where leakage of combustible gas is suspected Your air conditioner may fail to operate in air containing oils including machine oils sulfide gas near hot springs etc 4 CAUTION Because the compressor is located towards the rear of the unit this side will be heavier and more awkward to manipulate Therefore it is ...

Page 6: ...oner will resume to it s previous set temperature before sleep mode was activated This feature is meant to be used during the night time hours to prevent the room from getting too cold while you sleep and results in less compressor running time and reduced energy consumption Sleep mode may be cancelled by depressing the Sleep Mode button while the program is running FRESH AIR VENT Remains in Close...

Page 7: ...ght on off 12 Restore remote control default settings To operate the hand held remote control will require two AAA Alkaline batteries included Batteries should be replaced when a No signal beep is heard when attempting to program the main unit b The main unit does not respond to a command issued by the remote control Battery replacement 1 Slide the rear cover on the remote in the direction of the ...

Page 8: ...low 40 C 104 F To get better results wash with soapy water or a neutral cleaning agent 3 Rinse the filter with clean water and dry thoroughly before re installing End of Season Care 1 Operate the fan alone for half a day to dry out the inside of the unit 2 Turn off power and remove plug from wall socket 3 Clean filter 4 Store covered air conditioner in a dry location CAUTION When installing and or...

Page 9: ...ting to re start compressor overload tripped Noisy unit Loose parts Tighten loose parts Inadequate support Provide additional support to unit Odors Formation of mold mildew or Clean unit thoroughly algae on wet surfaces Place algaecide tablet in base pan Water dripping outside Hot and humid weather Condensation run off is normal under these conditions Water dripping inside Unit is not properly ang...

Page 10: ...tions representations or guarantees including any warranties conditions representations or guarantees under any Sale of Goods Act or like legislation or statue is hereby expressly excluded Save as herein provided Danby Products Limited Canada or Danby Products Inc U S A shall not be responsible for any damages to persons or property including the unit itself howsoever caused or any consequential d...

Page 11: ...ité énergétique EER Ventilateur vitesse de refroidissement Dimensions de l aire de refroidissement pieds2 Niveau du bruit dB Dimensions de l appareil Largeur Profondeur Hauteur Remarque Les spécifications peuvent être changées sans avis à titre d amélioration 14 8 16po 36 8cm 23 9 16po 59 8cm 20 1 4po 51 4cm 15 1 2po 39 4cm 21 12 16po 55 2cm Panneau de Commande Entrée D air Intérieur Sortie D Air ...

Page 12: ...uméro de modèle Numéro de série Date de l achat Nom et adresse du concessionnaire Veuillez vous reporter à la section du dépannage figurant dans ce manuel d utilisation et d entretien si l appareil ne fonctionne pas correctement Si cette suggestion ne résout pas le problème contactez un représentant autorisé des services ou appelez directement Danby sans frais au numéro 1 800 26 REMARQUE Conservez...

Page 13: ...à la masse adéquatement veuillez consulter un électricien qualifié 5 La prise murale pour 3 broches doit correspondre à la fiche à 3 broches sur le cordon de service fourni avec l appareil N utilisez PAS de fiches d adaptation Voir Tableau 2 pour les renseignements sur les prises de courant et les fusibles S il est nécessaire d utiliser une rallonge électrique pour brancher votre climatiseur utili...

Page 14: ...s de quincaillerie locaux G N installez PAS l appareil à un endroit où on soupçonne une fuite de gaz combustibles Votre climatiseur peut tomber en panne dans une atmosphère qui contient des huiles y compris des huiles pour machines des gaz sulfurés ou s il est près de sources d eau chaude etc MISE EN GARDE Comme le compresseur se trouve du côté des commandes de l unité côté droit ce côté est plus ...

Page 15: ...itesse de ventilateur fondé sur la réglage de la température Ventilateur Choisissez quatre réglage de ventilateur différentes Basse Moyenne Haut et Auto pendant les mode Frais et Ventilateur Remarque Pendant le mode sec il y a seulement une vitesse de ventilateur utilisée Réglage du Température et Minutrie Utilisée pour augmenter ou réduire le température par incréments de 10 et le minuterie en in...

Page 16: ...e au réglages par défaut Deux piles alcalines AAA sont requises pour le fonctionnement de la télécommande incluses Les piles devraient être remplacées quand a Aucun signal sonore bip n est entendu durant la programmation de l unité principale b L unité principale ne répond pas à un signal émis par la télécommande Remplacement des piles 1 Glisser le couvercle du compartiment des piles à l arrière d...

Page 17: ...ur de poussière muni d une brosse douce 2 104o F Pour obtenir de meilleurs résultats lavez avec une eau savonneuse ou un agent neutre de nettoyage 3 Rincez le filtre avec de l eau propre et séchez le à fond avant de le réinstaller Entretien hors saison 1 Faites fonctionner uniquement le ventilateur pendant une demi journée pour sécher l intérieur du climatiseur 2 Coupez le courant et enlevez la fi...

Page 18: ...branchement du cordon d alimentation à la source de courant Vérifiez le fusible ou le disjoncteur Placer le COMMUTATEUR DE SÉLECTION à une position autre que ARRÊT Nettoyez ou remplacez le filtre à air Vérifiez avec le concessionnaire si la capacité de l appareil est appropriée à son application Enlevez l objet qui obstrue la grille ou les volets extérieurs Arrêtez le climatiseur et attendez 5 min...

Page 19: ...ies conditions ou représentations en vertu de toute loi régissant la vente de produits ou de toute autre législation ou règlement semblables En vertu de la présente Danby Products Limitée Canada ou Danby Products Inc E U d A ne peut être tenue responsable en cas de blessures corporelles ou des dégâts matériels y compris à l appareil quelle qu en soit les causes Danby ne peut pas être tenue respons...

Page 20: ...e following information Product Type Model Number Part Number Part Description Climatiseur de pièce Le numéro de modèle de votre climatiseur se trouve sur la plaque d information qui se trouve sur le coté droit de l appareil par dessus le cordon d alimentation Toutes les pièces de rechange ou commandes spéciales sont disponibles de votre centre régional de service autorisé Pour exiger le service e...

Reviews: