background image

USE AND CARE

MANUAL

MANUEL

D'UTILISATION

Model • Modèle 

   

  DAC7037M

CAUTION:

Read and Follow All Safety Rules

and Operating Instructions Before

First Use of This Product.

PRÉCAUTION:

Veuillez lire attentivement 

les consignes de sécurité et les

instructions d'utilisation avant

l'utilisation initiale de 

ce produit.

Room Air Conditioner

Table of contents  . . . . . . . . . . . . . . . . . . . . . . . 1

Climatiseur de pièce

Table of contents  . . . . . . . . . . . . . . . . . . . . . . . 11    

Danby Products Limited, Guelph, Ontario Canada  N1H 6Z9

Danby Products Inc., Findlay, Ohio USA 45839-0669

R

10.01.

DAC7037M 2006-11-14 Y.P.Chen

Summary of Contents for Diplomat DAC7037M

Page 1: ... of This Product PRÉCAUTION Veuillez lire attentivement les consignes de sécurité et les instructions d utilisation avant l utilisation initiale de ce produit Room Air Conditioner Table of contents 1 Climatiseur de pièce Table of contents 11 Danby Products Limited Guelph Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45839 0669 R 10 01 ...

Page 2: ...erior Air Outlet Control Panel Specifications Voltage 115V 60Hz Cooling Capacity Btu h 7 000 Input Wattage 820w Energy Efficiency Rating EER 9 8 Fan Cooling Speeds 3 3 Cooling Area Coverage 200Sq ft 18 6m Noise Level dB 61 Unit Dimensions Width 18 8 16 470mm Depth 16 5 16 415mm Height 12 10 16 320mm Window Kit Dimensions Maximum Width 34 8 16 876mm Minimum Width 21 8 16 546mm Minimum Height 13 6 1...

Page 3: ...formation will be needed when you contact a Customer Service Representative Model Number DAC7037M Serial Number ___________________________________________________ Date of Purchase _________________________________________________ Dealer s Name and Address ________________________________________ ________________________________________ Refer to the trouble shooting section of this Use and Care Ma...

Page 4: ... Based on copper wire at 60 C temperature rating Table 2 Receptacle and Fuse Types Rated Volts 125 Amp 15 Wall Outlet Fuse Size 15 Time Delay Fuse Plug Type or circuit breaker 3 The power cord supplied with this air conditioner contains a current leakage detection device de signed to reduce the risk of fire Please refer to the section Power Supply Cord for details In the event the power supply cor...

Page 5: ...be highly efficient in energy savings Follow these recommendations for greater efficiency 1 Select thermostat setting that suits your comfort needs and leave thermostat at that chosen setting 2 The filter is very efficient in removing airborne particles Keep air filter clean Normally filter should be cleaned every 2 weeks More frequent cleaning may be necessary depending on indoor air quality 3 Us...

Page 6: ...bstacles obstructions and at least 30 above the floor or ground Curtains and other objects within a room should be prevented from blocking the air flow E Be certain the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes F DO NOT USE REGULAR EXTENSION CORDS WITH TH...

Page 7: ...n of the window frame Pull the window down until it rests just behind the front flange of the top L shaped mounting bracket See Fig 5 Expand the shutter frames fully on each side and secure the top of the frames to the window sash using one 3 4 19mm screw on each side and one in the L shaped mounting bracket See Fig 5 Secure the shutter clamp on each side of the lower shutter and secure to window ...

Page 8: ...tely NOTE Always allow 3 minutes before switching from one mode to another THERMOSTA T The thermostat automatically controls the compressor cooling cycle and maintains the selected room temperature To set the thermostat rotate the thermostat knob to the desired cooling setting 1 warmest 7 coldest The fan motor will continue to operate after the compressor cooling has cycled off This is normal HIGH...

Page 9: ...results wash with soapy water or a neutral cleaning agent 3 Rinse the filter with clean water and dry thoroughly before re installing End of Season Care 1 Operate the fan alone for half a day to dry out the inside of the unit 2 Turn off power and remove plug from wall socket 3 Clean filter 4 Store covered air conditioner in a dry location CAUTION When installing and or removing the air conditionne...

Page 10: ... 5 minutes before changed too quickly or attempting to re start compressor overload tripped Noisy unit Loose parts Tighten loose parts Inadequate support Provide additional support to unit Odors Formation of mold mildew or Clean unit thoroughly algae on wet surfaces Place algaecide tablet in base pan Water dripping outside Hot and humid weather Condensation run off is normal under these conditions...

Page 11: ...horized service depot or the unit is used for commercial application all obligations of Danby under this warranty shall be at an end EXCLUSIONS Save as herein provided Danby Products Limited Canada or Danby Products Inc U S A there are no other warranties conditions representations or guarantees express or implied made or intended by Danby Products Limited or its authorized distributors and all ot...

Page 12: ...ng service or ordering parts always provide the following information Product Type Model Number Part Number Part Description Climatiseur de pièce Le numéro de modèle de votre climatiseur se trouve sur la plaque d information qui se trouve sur le coté droit de l appareil par dessus le cordon d alimentation Toutes les pièces de rechange ou commandes spéciales sont disponibles de votre centre régiona...