background image

9

DIRECT DRAIN INSTRUCTIONS

DIRECT DRAIN

FEATURE

This dehumidifier is inclusive of a direct drain feature, located at the rear

of the cabinet. 

NOTE:

The drain hose is not included with the unit. The

direct drain feature is intended for use in basements inclusive of a floor

drain only.

NOTE:

Do not attempt to operate the direct drain 

feature using drain/stem pipes above ground level.

CONNECTING THE DIRECT DRAIN:

1)

Remove (cut away) drain cover located at the rear of

the unit (see Fig. 3) and remove the water tank located

at the front of the unit. 

2)

Cut drain hose to required length (to suit your needs).

You do not need any fittings on either end of the drain

hose. Insert one end of garden hose directly into drain

opening (see Fig. 4).

3)

Push firmly onto the drain connector until it stops (see

Fig. 5). 

NOTE:

This connection requires a pressure fit

application only. Make sure the hose is seated all the

way back on the drain connection nipple. 

4)

Re-install the water tank, making sure the water full

light turns “off”. If the light remains on, the tank has not

been properly installed. The water tank must always be

installed inside the cabinet whenever the direct drain

option is being used. 

5)

Position the dehumidifier as close as you can to the

floor drain.

6)

Position the open end of the drain hose directly over

the floor drain and start the unit.

7)

When the direct drain feature is not being used,

remove the drain hose from the direct drain nippe and

plug the Direct Drain opening (Fig. 3) with the rubber

cap provided. 

Fig. 3

Fig. 4

Fig. 5

Summary of Contents for DDR2509EE

Page 1: ... 1A 11 08 JF CAUTION Read and follow all safety rules and operating instructions before first use of this product MISE EN GARDE Veuillez lire attentivement les consignes de sécurité et les directives d utilisation avant l utilisation initiale de ce produit KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE If the Dehumidifier changes ownership be sure this manual accompanies the unit CONSERVER CES INSTR...

Page 2: ...t Specifications 4 INSTALLATION 5 Features 5 Unit Parts Identified 5 KEY PAD FUNCTIONS 6 OPERATING INSTRUCTIONS 7 Indicator Light Functions 7 Water Tank Operation 7 Dehumidifier Mode Instructions 8 Air Filter 8 DIRECT DRAIN INSTRUCTIONS 9 CARE AND MAINTENANCE 10 TROUBLESHOOTING 10 Warranty 11 1 TABLE OF CONTENTS ...

Page 3: ...iently moved from room to room within your home and set up in just minutes For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following information located on the rear wall of the water tank compartment Model Number Serial Number Date of Purchase This information will be necessary if your unit requires servicing and or for general inquiries T...

Page 4: ...ed three wire effectively grounded 120 Volt 60 Hertz alternating current circuit protected by a 15 ampere fuse equivalent fuse or circuit breaker The three prong grounding plug on the power cord should be plugged directly into a polarized three slot effectively grounded receptacle rated 110 120 V A C Improper connection of the equipment grounding conductor can result in a risk of electrical shock ...

Page 5: ...ns electrical and other technical data specific to this unit 5 To avoid the possibility of personal injury always disconnect the power supply before attempting to clean and or service the unit Model Number DDR2509EE Dehumidifying Capacity Pints Liters 25 11 8 Electrical Requirements 115 Volts 60 Hz Power Input Watts 380 Rated Amperage Dehumidifying 3 8 Air Flow Circulation High Fan Speed Cubic Fee...

Page 6: ... be between 6 C 42 8 F 35 C 95 F It is important to remember the efficiency of a dehumidifier will be effected influenced by the rate at which new humid air moisture is allowed to infiltrate the same space area To maintain efficiency the dehumidifier must be operated in an enclosed area Keep all doors and windows closed INSTALLATION LOCATION FEATURES Soft touch Electronic Control Key Pads Auto Sen...

Page 7: ...d in this mode The adjacent green indicator light illuminates to signify the continous mode is currently in operation 4 HUMIDITY UP This button allows you to increase the relative humidity setting Each time this button is pressed the RH value set ting is increased incrementally by 5 ranging from 35 80 5 HUMIDITY DOWN This button allows you to decrease the relative humidity setting Each time this b...

Page 8: ...e water tank is emptied and or correctly re positioned the dehumidifier will resume operation automatically NOTE It may take several minutes before operating conditions resume Factory Default Setting Each time the unit is disconnected re connected and or in the event of a power failure the electronic circuit board automatically defaults to the following factory setting Humidity Setting 60 Fan Spee...

Page 9: ...IFYING MODE SELECTION 1 To turn the unit on press the ON OFF button 2 Press the humidity UP or DOWN button to select a desired RH operating value 35 80 OR 2a Press the CONTINUOUS button When CONTINUOUS mode is selected the humidistat sensor will be by passed and the compressor will operate non stop regardless of humidity conditions FAN SPEED SELECTION 3 Select a fan speed on the keypad The speed y...

Page 10: ...nsert one end of garden hose directly into drain opening see Fig 4 3 Push firmly onto the drain connector until it stops see Fig 5 NOTE This connection requires a pressure fit application only Make sure the hose is seated all the way back on the drain connection nipple 4 Re install the water tank making sure the water full light turns off If the light remains on the tank has not been properly inst...

Page 11: ...y 3 Clean air filter thoroughly 4 Re package the unit in the original carton 5 Store the unit upright in a dry location TROUBLESHOOTING GUIDE Occasionally you may encounter some problems that are of a minor nature and a service call may not be necessary Use this troubleshooting guide to identify possible problems you may be experiencing If the unit continues to operate improperly call your local D...

Page 12: ...ther warranties conditions representations or guar antees including any warranties conditions representations or guarantees under any Sale of Goods Act or like legislation or statue is hereby expressly exclud ed Save as herein provided Danby Products Limited Canada or Danby Products Inc U S A shall not be responsible for any damages to persons or property including the unit itself howsoever caused...

Page 13: ...15 Spécifications de l unité 15 INSTALLATION 16 Caracteristiques 16 Composants de l appareil 16 FUNCTIONS DE TOUCHES du Tableau de Commande 17 OPÉRATION 18 Functions des témoins lumineux 18 Réceptacle à eau 18 Déshumidification 19 Filtre à Air 19 INSTRUCTIONS POUR DRAINAGE DIRECT 20 SOINS ET ENTRETIEN 21 DÉPANNAGE 21 Garantie 22 TABLE DES MATIÉRES ...

Page 14: ...sée nous vous suggérons de joindre une copie de votre reçu de caisse et ou facture d achat à cette page et d inscrire les renseignements suivants qui sont trouvés sur la plaque d identification du fabricant Celle ci est située sur le panneau arrière de l appareil Numéro de modèle Numéro de série Date d achat Ces renseignements seront requis si le service est demandé et ou si vous désirez obtenir d...

Page 15: ... reliée à la terre protégée par un fusible de 15 ampères ou disjoncteur ou fusible temporisé équivalent La fiche de branchement à trois broches du cordon d alimentation doit être branchée directement sur une prise de courant polarisée de même configuration et reliée à la terre conçu pour les circuits 110 120 V CA Le raccordement incorrect à la terre de cet appareil peut susciter un risque de choc ...

Page 16: ...a paroi arrière du compartiment du réceptacle à eau on y trouve les caractéristiques électriques et techniques spécificques de cet appareil 5 Pour éviter les risques de dommage corporel on doit toujours débrancher l appareil de la source d électricité avant d entreprendre des travaux de nettoyage ou d entretien REMARQUE La recherche ensuit toujours des améliorations Par conséquent ces informations...

Page 17: ...important de noter que l efficacité d un déshumidificateur sera influencée par la taux de réintroduction d air humide dans la pièce Pour obtenir la meilleure efficacité il convient de faire fonctionner le déshumidificateur dans un espace ferme Fermer toutes les portes et fenêtres INSTALLATION CHOIX DE L EMPLACEMENT CARACTÉRISTIQUES Clavier de commande tactile électronique Auto détection de l hygro...

Page 18: ...La valeur d humidité réglage ne peut pas être programmer dans cet mode 4 Augmentation de l humidité Cette touche vous permet d augmenter le réglage de l humidité relative Chaque fois que cette touche est appuyez l humidité relative est progressivement augmentée par 5 varie de 35 80 5 Diminution de l humidité Cette touche vous permet de diminuer le réglage de l humidité relative Chaque fois que cet...

Page 19: ...ant la remise en marche du déshumidificateur Configuration de réglage de l usine Chaque fois qu on branche l appareil après l avoir débranché ou après une interruption de l alimentation le circuit de commande électronique adopte automatiquement par défaut la configuration de réglage définie à l usine Réglage delon l hygrométrie ambiante 60 Vitesse ventilateur Haute NOTE À l occasion d une interrup...

Page 20: ...n taux d hygrométrie qui permet le fonctionnement de l appareil SÉLECTION DU MODE DE DÉSHUMIDIFICATION 1 Appuyer sur le bouton ON OFF pour commander la mise en marche de l appareil 2 Appuyez la touche d humidité UP ou DOWN pour sélectionner la valeur de l humidité relative désirez 35 80 OU 2a Appuyez sur la touche Continu Quand la mode continu est sélectionnée le compresseur fonctionne sans arrêt ...

Page 21: ...qu à la position de butée Fig 5 NOTE la friction assure la rétention du tuyau au niveau de cette connextion veiller à ce que le tuyau soit complèment enfoncé sur le raccord de drainage 4 Réinstaller le réceptacle à eau vérifier que le témoin receptacle à eau plein s éteint Si le témoin reste illuminé c est parce que le réceptacle à eau n a pas été correctement installé Même lorsque la fonction de ...

Page 22: ...rfaitement le filtre à air 4 Remettre l appareil dans son emballage d origine 5 Remiser l appareil verticalement en un lieu sec DÉPANNAGE Quelques problèmes mineurs peuvent occasionellement survenir que l utilisation pourra résoudre Utiliser le guide de diagnostic ci dessous pour identifier les éventuels problèmes qui se manifesteraient Si l appareil persiste à ne pas fonctionner correctement obte...

Page 23: ...itions ou représentations y compris les garanties conditions ou représentations en vertu de toute loi régissant la vente de produits ou de toute autre législation ou règlement semblables En vertu de la présente Danby Products Limitée Canada ou Danby Products Inc E U d A ne peut être tenue responsable en cas de blessures corporelles ou des dégâts matériels y compris à l appareil quelle qu en soit l...

Page 24: ...ce or ordering parts always provide the following information Product Type Model Number Part Number Part Description Le numéro de modèle se trouve sur la plaque d information sur le panneau arrière de l appareil Toutes les pièces de rechange ou commandes spéciales sont disponibles à votre centre de service régional autorisé Pour obtenir le service et ou la localité de votre centre de service régio...

Reviews: