background image

FREQUENTLY ASKED QUESTIONS

7

What is the best humidity setting?

We recommend setting your dehumidifi er between 
40-45%.

Is the air that comes out of the dehumidifi er 

supposed to be hot?

Yes, usually this air feels warm.

Why isn’t the dehumidifi er collecting any 

water?

There may not be enough humidity in your 
environment or the relative humidity might be set 
higher than ambient humidity.

Does the fan run continuously?

In continuous mode, the fan will run continuously.
In smart dehumidify mode or manual mode the fan 
will cycle on and off.

Can I use an extension cord?

No, the dehumidifi er is built to operate using the 
power cord provided.

Does the timer cycle on and off forever?

The on and off timers can be used at the same time 
however, they will only cycle one time and then 
resume normal functioning.

How do I hook up my direct drain?

Remove the cover from the continuous drain outlet 
and attach the provided connector and drain hose 
to the back of the appliance. Direct the other end of 
the drain hose to a bucket or fl oor drain. 

Does the fi lter light come on when it is 

dirty?

The fi lter light comes on automatically after about 
250 hours of use even if the fi lter is clean. Clean the 
fi lter and then press the fi lter button to turn the fi lter 
light off.

What is the plastic piece in the bucket?

This rounded piece is called a buckle and is clipped 
on to the back of the dehumidifi er. It is used to wrap 
the power cord during long term storage of the 
dehumidifi er.

TROUBLESHOOTING

Appliance will not operate

•  Plug is not fully inserted into the wall outlet
•  Blown fuse or circuit breaker
•  Ambient humidity is lower than the set humidity
•  Bucket is full or is not in the proper position

Insuffi cient dehumidifying

• Air 

fi lter is dirty

•  Blocked air fl ow
•  Appliance size is too small for application
•  Ambient humidity is lower than the set humidity

Noise

• Air 

fi lter is dirty

•  Bucket is not in proper position
•  Floor surface is not level

Odors

•  Formation of mold or mildew on internal wet 

surfaces

•  Place an algaecide tablet in the water bucket

Water on fl oor

•  Hose connection is loose
•  Drain cover has been removed

Frost build up

•  When ambient temperature is below 5°C (41°F) 

frost may form

•  Switch the appliance to fan only mode until the 

frost melts

Summary of Contents for DDR050BJPWDB-RF

Page 1: ...A 45840 Imprim au Canada ou aux tats Unis Impreso en Canad o EE UU Trademark of Danby Products Marque de commerce de Danby Products Marca registrada de Danby Products www Danby com Printed in Canada...

Page 2: ...use this dehumidi er for commercial or industrial applications GROUNDING INSTRUCTIONS This appliance must be grounded Grounding reduces the risk of electrical shock by providing an escape wire for th...

Page 3: ...ting it will stabilize between 45 55 Press the humidity adjust buttons to cancel this feature 6 Filter button The check lter light will illuminate after 250 hours of operation After cleaning the lter...

Page 4: ...ns to set the humidity between 40 45 It is normal for the dehumidi er to exhaust warm air from the air outlet The power cord storage band can be found in the water bucket and it can be installed by pr...

Page 5: ...an be removed using the provided connector and drain hose Before using any automatic drain functions check that all drain ports are clean There is one drain port inside the bucket compartment of the a...

Page 6: ...e insert the pump drain hose into the pump drain hose outlet for depth of 15 mm at least or until it clicks and make sure the hose is secure so there are no leaks Direct the other end of the hose to a...

Page 7: ...ved or not in the correct position CLEANING To avoid possible electric shock ensure that the appliance is unplugged before performing any cleaning or maintenance The outside of the appliance can be wi...

Page 8: ...bucket or oor drain Does the lter light come on when it is dirty The lter light comes on automatically after about 250 hours of use even if the lter is clean Clean the lter and then press the lter but...

Page 9: ...A 45840 Telephone 419 425 8627 FAX 419 425 8629 04 13 1 800 263 2629 Warranty Service Carry In C ERTIFIE D C E R T I F I E D This quality product is warranted to be free from manufacturer s defects i...

Page 10: ...pas ce d shumidi cateur pour des applications commerciales ou industrielles INSTRUCTIONS DE MISE LA TERRE Cet appareil doit tre mis la terre La mise la terre r duit le risque de choc lectrique en fou...

Page 11: ...f che la s lection lors de la programmation de l humidit ou de la minuterie 4 Bouton de la pompe appuyez pour activer la pompe de vidange Assurez vous qu un tuyau de vidange est connect avant de d mar...

Page 12: ...bande de rangement du cordon d alimentation se trouve dans le seau d eau et peut tre install e en la pressant l arri re de l armoire jusqu ce qu elle s enclenche MINUTEUR Arr t automatique 1 Lorsque l...

Page 13: ...s Avant d utiliser les fonctions de vidange automatique v ri ez que tous les ori ces de vidange sont propres Il y a un ori ce de vidange l int rieur du compartiment du seau de l appareil retirez le se...

Page 14: ...irez le ruban adh sif xe ins rez le tuyau de vidange de la pompe dans la sortie du tuyau de vidange de la pompe sur une profondeur d au moins 15 mm ou jusqu ce qu il s enclenche et assurez vous que le...

Page 15: ...a bonne position NETTOYAGE Pour viter tout risque d lectrocution assurez vous que l appareil est d branch avant d effectuer un nettoyage ou une maintenance L ext rieur de l appareil peut tre nettoy av...

Page 16: ...siphon de sol Le voyant du ltre s allume t il lorsqu il est sale Le voyant du ltre s allume automatiquement apr s environ 250 heures d utilisation m me si le ltre est propre Nettoyez le ltre puis app...

Page 17: ...D Cet appareil de qualit est garantie exempt de tout vice de mati re premi re et de fabrication s il est utilis dans les conditions normales recommand es par le fabricant Cette garantie n est offerte...

Page 18: ...DE CONEXION A TIERRA Este aparato debe estar conectado a tierra La puesta a tierra reduce el riesgo de descarga el ctrica proporcionando un cable de escape para la corriente el ctrica Este aparato tie...

Page 19: ...en un rango de 30 a 90 De lo contrario muestra la selecci n al programar la humedad o el temporizador 4 Bot n de bomba presione para activar la bomba de drenaje Aseg rese de que haya una manguera de...

Page 20: ...salida de aire La banda de almacenamiento del cable de alimentaci n se puede encontrar en el cubo de agua y se puede instalar presion ndola en la parte posterior del gabinete hasta que haga clic TEMP...

Page 21: ...los puertos de drenaje est n limpios Hay un puerto de drenaje dentro del compartimiento del balde del aparato retire el balde para verlo Hay un puerto de drenaje en la parte posterior del aparato don...

Page 22: ...inserte la manguera de desag e de la bomba en la salida de la manguera de desag e de la bomba hasta una profundidad de al menos 15 mm o hasta que haga clic y aseg rese de que la manguera est segura p...

Page 23: ...la posici n correcta LIMPIEZA Para evitar posibles descargas el ctricas aseg rese de que el aparato est desenchufado antes de realizar cualquier limpieza o mantenimiento El exterior del aparato se pu...

Page 24: ...io La luz del ltro se enciende autom ticamente despu s de aproximadamente 250 horas de uso incluso si el ltro est limpio Limpie el ltro y luego presione el bot n del ltro para apagar la luz del ltro Q...

Page 25: ...bra siempre y cuando la unidad se utilice bajo las condiciones normales de funcionamiento para las que fue dise ado Esta garant a est solamente disponible para la persona que haya comprado originalmen...

Reviews: