20
INSTALLATION INSTRUCTIONS
Step 4: Connect pipes
When connecting refrigerant pipes, be careful not to use excessive torque or
to deform the piping in any way. Connect the low pressure pipe fi rst and then
connect the high pressure pipe.
Note: When bending connective refrigerant piping, the minimum bending radi-
us is 10 cm (3.9 in).
CONNECTING PIPING TO INDOOR UNIT
1. Align the center of the two pipes that will be connected.
2. Tighten the fl are nut as tightly as possible by hand.
3. Using a spanner, grip the nut on the unit tubing.
4. While fi rmly gripping the nut on the unit tubing, use a torque wrench to tighten the fl are nut according
to the torque values in the torque requirements table below. Loosen the fl aring nut slightly, then tighten
again.
Excessive force can break the nut or
damage the refrigerant piping. Do not
exceed the torque requirements shown
in the table below.
TORQUE REQUIREMENTS
Outer Diameter of Pipe (mm)
Tightening Torque (N•cm)
Ø 6 / Ø 6.35
15 ~ 25
Ø 9 / Ø 9.52
35 ~ 40
Ø 12 / Ø 12.7
45 ~ 60
Ø 15.88
73 ~ 78
Ø 19.05
75 ~ 80
Summary of Contents for DAS120GBHWDB
Page 4: ...3 INSTALLATION INSTRUCTIONS INSTALLATION SUMMARY INDOOR UNIT ...
Page 5: ...4 INSTALLATION INSTRUCTIONS INSTALLATION SUMMARY INDOOR UNIT L1 L2 S ...
Page 30: ...29 RÉSUMÉ DE L INSTALLATION UNITÉ INTÉRIEURE INSTRUCTIONS D INSTALLATION ...
Page 31: ...30 RÉSUMÉ DE L INSTALLATION UNITÉ INTÉRIEURE INSTRUCTIONS D INSTALLATION ...
Page 56: ...55 RESUMEN DE LA INSTALACIÓN UNIDAD INTERIOR INSTRUCCIONES DE INSTALACIÓN ...
Page 57: ...56 RESUMEN DE LA INSTALACIÓN UNIDAD INTERIOR INSTRUCCIONES DE INSTALACIÓN ...