Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
FOR YOUR SAFETY:
Read these instructions carefully before operating the unit.
ELECTRICAL SPECIFICATIONS
1. All wiring must comply with local and national electrical codes and must be installed by a qualifi ed electrician. If you
have any questions regarding the following instructions, contact a qualifi ed electrician.
2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3. This 115V or 230/208V air conditioner uses 11.8 or less nameplate amps and may be used in any properly wired,
general purpose household receptacle. See
Table 1
for specifi cations for individual branch circuit.
4. For your safety and protection, this unit is grounded through the powercord plug when plugged into a matching wall
outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualifi ed electrician.
5. The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters.
See
Table 2
for receptacle and fuse information.
6. The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of
the unit, above the powercord.
TABLE 1 - DAC180BBUWDB
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
7.0/7.5 14
AWG- American Wire Guage
*Based on copper wire at 105°C (221°F) temperature
rating.
TABLE 2
Recept and Fuse Types
Model
DAC180BBUWDB
Rated Volts 240
240
250
Amps 15
15
30
Wall Outlet
Fuse Size 15
15
20
Time Delay Fuse Plug Type
(or Circuit Breaker)
2
TABLE 1 - DAC250BBUWDB
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
10.8/11.8 12
AWG- American Wire Guage
*Based on copper wire at 105°C (221°F) temperature
rating.
TABLE 2
Recept and Fuse Types
Model
DAC250BBUWDB
Rated Volts 240
240
250
Amps 20
15
30
Wall Outlet
Fuse Size 20
15
20
Time Delay Fuse Plug Type
(or Circuit Breaker)
WARNING: Do not under any corcumstances, cut, remove
or bypass the grounding prong on the power plug.