background image

Your Danby appliance is designed to be highly efficient in energy 
savings. 

Follow these recommendations for greater efficiency. 

1) 

Select a thermostat setting that suits your comfort

needs and leave at that chosen setting. 

2) 

The filter is very efficient in removing airborne 

particles. Keep the air filter clean. Normally, filters

should be cleaned every 2 weeks. More frequent 

cleaning may be necessary depending on indoor air

quality. 

3) 

Use drapes, curtains or shades to keep direct 

sunlight from penetrating and heating room, but do not

allow drapes or curtains to obstruct the air flow around

the unit.

4)

Start your air conditioner before the outdoor air

becomes hot and uncomfortable, to avoid an initial

period of discomfort while the unit is cooling off the

room. 

5)

When outdoor temperatures are cool enough, use

HIGH

or 

LOW FAN

only. This circulates indoor

air, providing some cooling comfort, and utilizes less

electricity than when operating on a cooling setting. 

ENERGY-

SAVING TIPS

TOOLS NEEDED FOR INSTALLATION:

Screw Drivers:  

Both Phillips and flat head

Power Drill:  

1/8 inch (3.2mm) diameter drill bit

Pencil

Scissors

Measuring Tape

Carpenters Level

ELECTRIC SHOCK HAZARD:

To avoid the possibility of personal injury, disconnect power to the

unit before installing or servicing. 

3/4” (19.1mm)

screws (9)

*Factory installed

on some models

Safety Lock (1)

Adhesive

Foam Seal(1)

Sash bracket (2)

“L” Shaped

mounting 

bracket (1)

INSTALLATION HARDWARE

Your Room Air Conditioner is designed for easy 

installtion in a single or double-hung window. This unit is 

NOT

designed for vertical (slider type) windows and/or through-the-wall

applications.

NOTE:

Save the shipping carton and packing materials for future

storage or transport of the unit. From carton, remove the plastic bag

containing the installation hardware kit necessary for the installation

of your air conditioner. Please check the contents of hardware kit

against the corresponding model check list, prior to installation of the

unit.

See Fig. 1

.

CAUTION:

Because the compressor is located on the controls

side of the unit (left side), this side will be heavier and more 

awkward to manipulate. Inadequate support on control side of the

unit can result in personal injury and damage to your unit and 

property. Therefore, it is recommended that you have someone assist

you during the installation of this unit. 

Side Curtain RH (1)

Side Curtain LH (1)

3/8” (9.5mm) screws

(4) (*Factory

installed on some

models)

NOTE: Your unit is designed to evaporate condensation under normal conditions. However, under

extreme humidity conditions, excess condensation may cause basepan to overflow to the outside. The

unit should be installed where condensation run-off cannot drip on pedestrains or neighboring 

properties

Fig. 1

IMPORTANT SAFETY INFORMATION (cont’d)

INSTALLATION

3

Summary of Contents for dac12077ee

Page 1: ...te du climatiseur ce manuel doit tre inclus avec l appareil CAUTION Read and follow all safety rules and operating instructions before first use of this product MISE EN GARDE Veuillez lire attentiveme...

Page 2: ...ate of Purchase This information will be necessary if your unit requires servicing and or for general inquiries To contact a Customer Service Representative call Danby TOLL FREE 1 800 26 1 800 263 262...

Page 3: ...ers See Table 2 for receptacle and fuse information If it is necessary to use an extension cord to connect your air conditioner use an approved air conditioner extension cord only available at most lo...

Page 4: ...crews 9 Factory installed on some models Safety Lock 1 Adhesive Foam Seal 1 Sash bracket 2 L Shaped mounting bracket 1 INSTALLATION HARDWARE Your Room Air Conditioner is designed for easy installtion...

Page 5: ...electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes F DO NOT install uni...

Page 6: ...side and secure the top of the frames to the window sash using one 3 4 screw on each side and one in the L shaped mounting bracket Fig 5 Secure the shutter clamp on each side of the lower shutter and...

Page 7: ...the program is complete the air conditioner will resume to its previous set temperature before sleep mode was activated This feature is meant to be used during the night time hours to prevent the roo...

Page 8: ...cklight on off 12 Restore remote control default settings To operate the hand held remote control will require two AAA Alkaline batteries included Batteries should be replaced when a No signal beep is...

Page 9: ...thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results wash with soapy water or...

Page 10: ...or outdoor louvres Turn the unit off and wait 5 minutes before attempting to restart Tighten loose parts Provide additional support to unit Clean unit thoroughly Place algaecide tablet in base pan Con...

Page 11: ...le Num ro de s rie Date d achat Ces renseignements seront requis si le service est demand et ou si vous d sirez obtenir des renseignements suppl mentaires Pour consulter un Repr sentant du service la...

Page 12: ...en qualifi 5 La prise murale doit correspondre la fiche 3 broches sur le cordon de service fourni avec l appareil N utilisez PAS de fiches d adaptation Voir Tableau 2 pour les renseignements sur les p...

Page 13: ...lus difficile manipuler Un soutien inappropri du c t des commandes de l appareil peut causer des blessures et endommager l appareil et d autres biens mobiliers C est pourquoi il est recommand que quel...

Page 14: ...bloquer le flux d air E Assurez vous que la prise lectrique appropri e se trouve la port e de l installation N utilisez qu un circuit prise unique calcul 15 amp res Tout le c blage doit tre conforme a...

Page 15: ...volets compl tement de chaque c t et fixez le haut des structures au cadre de la fen tre en utilisant une vis de 3 4 po et une rondelle de s curit sur chaque c t Fig 5 Coupez la bande mousse adh sif a...

Page 16: ...un 1 heures la nouvelle temp rature est maintenue pendant sept 7 heures Une fois que le programme est complet le climatiseur reprendra la temp rature de climatisation votre pr r glage avant que le mod...

Page 17: ...es arrangements de t l commande au r glages par d faut Deux piles alcalines AAA sont requises pour le fonctionnement de la t l commande incluses Les piles devraient tre remplac es quand a Aucun signal...

Page 18: ...un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneuse ou un agent neutre d...

Page 19: ...strue la grille ou les volets ext rieurs Arr tez le climatiseur et attendez 5 minutes avant de le remettre en marche Serrez les pi ces qui sont desserr es ou ont de jeu Fournissez un support suppl men...

Page 20: ...esting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description Le num ro de mod le se trouve sur la plaque d information sur le pannea...