Important Safety Information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

The following checks shall be applied to installations 

using fl ammable refrigerants:

•  The charge size is in accordance with the room 

size within which the refrigerant containing 

parts are installed. 

•  The ventilation machinery and outlets are 

operating adequately and are not obstructed.

•  If an indirect refrigerating circuit is being used, 

the secondary circuit shall be checked for the 

presence of refrigerant.

•  Marking to the equipment continues to be visible 

and legible. Markings and signs that become 

illegible must be corrected.

•  Refrigeration pipe or components are installed in 

a position where they are unlikely to be exposed 

to any substance which may corrode refrigerant 

containing components, unless the components 

are constructed of materials which are inherently 

resistant to being corroded or are suitable 

protected against being corroded.

9.  Checks to electrical devices: 

Repair and 

maintenance to electrical components shall 

include initial safety checks and component 

inspection procedures. If a fault exists that 

could compromise safety, then no electrical 

supply shall be connected to the circuit until it 

is satisfactorily dealt with. If the fault cannot 

be corrected immediately but it is necessary to 

continue operation, an adequate temporary 

solution shall be used. This shall be reported to 

the owner of the equipment so all parties are 

advised.

Initial safety checks shall include:

•  That capacitors are discharged. This shall be 

done in a safe manner to avoid possibility of 

sparking.

•  That no live electrical components and wiring 

are exposed while charging, recovering or 

purging the system.

•  That there is continuity of earth bonding.

Repairs to sealed components

1.  During repairs to sealed components, all 

electrical supplies shall be disconnected from 

the equipment being worked upon prior to any 

removal of sealed covers, etc. If it is absolutely 

necessary to have an electrical supply to 

equipment during servicing then a permanently 

operating form of leak detection shall be located 

at the most critical point to warn of a potentially 

hazardous situation.

2.  To ensure that by working on electrical 

components the casing is not altered in such 

a way that the level of protection is affected, 

particular attention shall be paid to the 

following:

•  Damage to cables, excessive number of 

connections, terminals not made to original 

specifi cation, damage to seals, incorrect fi tting 

of glands, etc.

•  Ensure the apparatus is mounted securely.

•  Ensure that seals or sealing materials have 

not degraded such that they no longer serve 

the purpose of preventing the ingress of 

fl ammable atmospheres. Replacement parts 

shall be in accordance with the manufacturer’s 

specifi cations.

Note: The use of silicon sealant may inhibit the 

effectiveness of some types of leak detection 

equipment. Intrinsically safe components do not 

have to be isolated prior to working on them.

Repair to intrinsically safe components

Do not apply any permanent inductive or 

capacitance loads to the circuit without ensuring 

that this will not exceed the permissible voltage 

and current permitted for the equipment in use. 

Intrinsically safe components are the only types that 

can be worked on while live in the presence of a 

fl ammable atmosphere. The test apparatus shall 

be at the correct rating. Replace components only 

with parts specifi ed by the manufacturer. Other 

parts may result in the ignition of refrigerant in the 

atmosphere from a leak.

4

Summary of Contents for DAC100B5WDB

Page 1: ...OHIO USA 45840 OWNER S MANUAL MANUEL DU PROPRI TAIRE MANUAL DEL PROPIETARIO www Danby com AIR CONDITIONER Owner s Manual 1 16 CLIMATISEUR Manual du propri taire 17 32 AIRE ACONDICIONADO Manual del pr...

Page 2: ...ide the original purchase receipt to validate your warranty and receive service Model Number _________________________________________________ Serial Number ___________________________________________...

Page 3: ...of the appliance just above the power cord contains electrical and other technical data This appliance is not intended for use by persons including children whose physical sensory or mental capabilit...

Page 4: ...nt detector prior to and during work to ensure the technician is aware of potentially ammable atmospheres Ensure that the leak detection equipment being used is suitable for use with ammable refrigera...

Page 5: ...recovering or purging the system That there is continuity of earth bonding Repairs to sealed components 1 During repairs to sealed components all electrical supplies shall be disconnected from the equ...

Page 6: ...d Extreme care shall be taken not to over ll the refrigeration system Prior to recharging the system it shall be pressure tested with OFN The system shall be leak tested on completion of charging but...

Page 7: ...hat there are labels on the equipment stating the equipment contains ammable refrigerant Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good...

Page 8: ...ce should be installed where condensation cannot drip on pedestrians or neighboring properties Provide suf cient clearance around the appliance to allow ample air circulation The rear of the appliance...

Page 9: ...w sash down until it rests just behind the front ange of the L shaped mounting bracket Expand the side curtains on each side and secure the top of the frames to the window sash using one 13 mm 1 2 scr...

Page 10: ...decrease buttons for 3 seconds to change between C and F 4 Power Button Used to turn the appliance on or off A Energy saver mode indicator B Wireless connection indicator C Cool mode indicator D Fan m...

Page 11: ...bstruction between the receiver and remote may cause signal interference limiting the ability to program the main unit REMOTE CONTROL 1 Power Button Used to turn the appliance on or off 2 Mode Button...

Page 12: ...Visit https www danby com support apps to download the application and learn about its operation 11 SHORTCUT FUNCTION The shortcut function is only available on the remote control It can be used to se...

Page 13: ...all for service L0 Displayed when the room temperature is lower than 0 C 32 F HI Displayed when the room temperature is higher than 37 C 99 F AS Room temperature sensor error ES Evaporator temperature...

Page 14: ...and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against interference in a residential...

Page 15: ...depot Any appliance requiring service outside the limited boundaries of In Home Service will be the consumer s responsibility to transport at their own expense to the original point of purchase or a...

Page 16: ...e re u d achat original pour valider votre garantie et recevoir le service Num ro de mod le _____________________________________________ Num ro de serie ______________________________________________...

Page 17: ...plosion Fluide frigorig ne in ammable utilis Ne pas endommager le circuit de r frig rant Assurez vous que les r parations sont effectu es par du personnel autoris par l usine a n de minimiser les domm...

Page 18: ...ue le technicien est conscient des atmosph res potentiellement in ammables Assurez vous que l quipement de d tection des fuites utilis convient aux uides frigorig nes in ammables c est dire qu il ne p...

Page 19: ...mise la terre R paration de composants scell s 1 Lors de la r paration de composants scell s toutes les alimentations lectriques doivent tre d branch es de l quipement utilis avant toute d pose de co...

Page 20: ...r me doit tre pris pour ne pas trop remplir le syst me de r frig ration Avant de recharger le syst me il doit tre test sous pression avec OFN Le syst me doit tre soumis un test d tanch it la n du char...

Page 21: ...sur l quipement indiquant que celui ci contient du r frig rant in ammable R cup ration Lorsque vous retirez du uide frigorig ne d un syst me que ce soit pour un entretien ou une mise hors service il e...

Page 22: ...s le mur Assurez vous que la fen tre et le cadre sont structurellement sains et exempts de bois sec ou pourri Installez le climatiseur dans une fen tre sur un c t du b timent qui favorise plus d ombre...

Page 23: ...p rieure jusqu ce qu il repose juste derri re la bride avant du support de montage en forme de L D veloppez les rideaux lat raux de chaque c t et xez le haut des cadres au ch ssis de fen tre l aide d...

Page 24: ...d alimentation Utilis pour allumer ou teindre l appareil A Indicateur de mode d conomie d nergie B Indicateur de connexion sans l C Indicateur de mode froid D Indicateur de mode de ventilation E Af c...

Page 25: ...de programmer l unit principale T L COMMANDE 1 Bouton d alimentation Utilis pour allumer ou teindre l appareil 2 Bouton de mode Utilis pour choisir le mode de fonctionnement 3 Bouton du ventilateur Ut...

Page 26: ...l Rendez vous sur https www danby com support apps pour t l charger l application et d couvrir son fonctionnement FONCTION DE RACCOURCI La fonction de raccourci est uniquement disponible sur la t l c...

Page 27: ...ambiante est inf rieure 0 C 32 F HI S af che lorsque la temp rature ambiante est sup rieure 37 C 99 F AS Erreur du capteur de temp rature ambiante ES Erreur du capteur de temp rature de l vaporateur N...

Page 28: ...orme aux limites d un appareil num rique de classe B conform ment la partie 15 des r gles de la FCC Ces limites sont con ues pour fournir une protection raisonnable contre les interf rences dans une i...

Page 29: ...iers vingt quatre 24 mois toutes les pi ces fonctionnelles de ce produit qui s av rent d fectueuses seront r par es ou remplac es selon le choix du garant sans frais l acheteur initial Danby se r serv...

Page 30: ...ci n para obtener un servicio bajo garant a Debe proporcionar el recibo de compra original para validar su garant a y recibir servicio N mero de modelo _____________________________________________ N...

Page 31: ...STRUCCIONES DE SEGURIDAD REQUERIMIENTOS DE SEGURIDAD PELIGRO Riesgo de incendio o explosi n Refrigerante in amable utilizado No da e el circuito de refrigerante Aseg rese de que el servicio sea realiz...

Page 32: ...nte el trabajo para garantizar que el t cnico tenga conocimiento de las atm sferas potencialmente in amables Aseg rese de que el equipo de detecci n de fugas que se est utilizando sea adecuado para el...

Page 33: ...ientras se est cargando recuperando o purgando el sistema Que hay continuidad de la uni n de la tierra Reparaciones a componentes sellados 1 Durante las reparaciones de componentes sellados todos los...

Page 34: ...ener mucho cuidado de no sobrecargar el sistema de refrigeraci n Antes de recargar el sistema se someter a prueba de presi n con OFN El sistema debe ser probado contra fugas al nalizar la carga pero a...

Page 35: ...o que indiquen que el equipo contiene refrigerante in amable Recuperaci n Cuando se retira refrigerante de un sistema ya sea para servicio o cierre se recomienda que todos los refrigerantes se elimine...

Page 36: ...Aseg rese de que la ventana y el marco est n estructuralmente rmes y libres de madera seca o podrida Instale el aire acondicionado en una ventana en un costado del edi cio que favorezca m s sombra que...

Page 37: ...ia abajo hasta que descanse justo detr s de la brida delantera del soporte de montaje en forma de L Expanda las cortinas laterales en cada lado y asegure la parte superior de los marcos al marco de la...

Page 38: ...nte 3 segundos para cambiar entre C y F 4 Bot n de encendido Se utiliza para encender o apagar el aparato A Indicador de modo de ahorro de energ a B Indicador de conexi n inal mbrica C Indicador de mo...

Page 39: ...r la temperatura establecida Mantenga presionados los botones de aumento y disminuci n durante 3 segundos para cambiar entre C y F 12 Pantalla LED Muestra la temperatura con gurada y el ajuste del tem...

Page 40: ...aplicaci n y obtener informaci n sobre su funcionamiento FUNCI N DE ACCESO DIRECTO La funci n de acceso directo solo est disponible en el control remoto Se puede utilizar para establecer un ajuste fa...

Page 41: ...Si el error persiste llame al servicio t cnico L0 Se muestra cuando la temperatura ambiente es inferior a 0 C 32 F HI Se muestra cuando la temperatura ambiente es superior a 37 C 99 F AS Error del se...

Page 42: ...CAN ICES 3 B Este equipo ha sido probado y cumple con los l mites para un dispositivo digital de Clase B de acuerdo con la Parte 15 de las Reglas de la FCC Estos l mites est n dise ados para proporcio...

Page 43: ...del rea limitada de Servicio en Domicilio el cliente ser responsable por transportar dicho artefacto hasta el Taller de Servicio Autorizado mas cercano Si el electrodom stico est instalado en un lugar...

Page 44: ...MODEL MOD LE MODELO Printed in China Imprim en Chine Impreso en China Danby Products Limited Guelph ON Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45840 DAC100B5WDB DAC120B5WDB 6...

Reviews: