Check that the air conditioner is tilted downwards to the outside, about 3° to 4°, as shown in
Fig. 7
. After proper installa-
tion, condensed water should not drain from the overfl ow drain hole during normal use. If you notice water leaking out,
check the angle of tilt, and make any necessary adjustments. However, on a very humid day, water leakage can occur –
this is normal.
Note: To achieve 3° to 4°, you must measure the H, see fi gure 7.
Measure the tilt angle frThe distance H should be approximately 3/4 in. to 1 in. (19 mm - 2.5 cm) for DAC080EUB6GDB.
The distance H should be approximately 1 in. to 1 3/8 in. (2.5 cm - 3.5 cm) for DAC100EUB4GDB and DAC120EUB-
6GDB.
ASSEMBLY AND INSTALLATION (cont’d)
Fig. 7
Measure the tilt angle from the cabinet’s edge
WINDOW
: approximately 3/4 in. (19 mm) to
1 in. (2.5 cm) for
: approximately 1 in. (2.5 cm) to
1 3/8 in. (3.5 cm) for
INSTALLATION INSTRUCTIONS
DAC080EUB6GDB
DAC100EUB4GDB
DAC120EUB6GDB
4. Installing the Energy Effi cient Foam Insert
•
After the unit is installed in the window, measure the width of the side curtain.
•
If necessary, cut the foam insert down to the width of the side curtain.
•
Slide the foam insert into the side curtain.
•
Repeat for the other side. (See below)
NOTE: Apply the supplied weather-stripping where needed (cracks and spaces between the foam insert, window
kit and window frame).