background image

Operating In

s

tructions

USING THE REMOTE

CONTROL

Location of the remote controller.

Use the remote controller within a distance of 8

meters from the appliance, pointing it towards

the receiver. Reception is confirmed by a beep.

CAUTION

• 

The air conditioner will not operate if curtains, doors or other

materials block the signals from the remote controller to the

indoor unit.

• 

Prevent any liquid from falling into the remote controller. Do not

expose the remote controller to direct sunlight or heat.

• 

If the infrared signal receiver on the indoor unit is exposed to

direct sunlight, the air conditioner may not function properly. Use

curtains to prevent the sunlight from falling on the receiver.

• 

If other electrical appliances react to the remote controller, either

move these appliances or call the service depot.

8

While the Air Conditioner is on (Auto-Off):

1)

Press the 

Auto-T

imer button twice and the 

adjacent

 

Auto-Of

indicator

light 

will

 

illuminate.

2)

Use the 

Temp/T

imer control cursors to select a 

delayed

 

Of

f time of 

up

to 24 

hours.

3)

The time you 

selected

 

will

 

appear

 in the LED 

display

. The Auto On 

and

Auto 

Of

f timer can 

operate

 

during

 the same 

program

 by 

defining

 

the

Auto-Of

p

arameters 

immediately

 

af

ter the Auto On 

parameters.The

Auto-T

imer may be 

cancelled

 at any time by 

turning

 the unit 

On/Off.

For example,if you want to let the machine on one hour later and last 

for one hour and then stop,set auto on “1” and auto off “2”.

/

E

T

N

W N

I

A

8m

AUTO-TIMER:

Used to 

initiate

 the Auto On/ Auto 

Of

timer.

While the Air Conditioner is off (Auto-On):

1)

Press the 

Auto-T

imer button once and the 

adjacent

  Auto-On 

indicator

light 

will

 

illuminate.

2)

Use the 

Temp/T

imer control cursors to select a 

delayed

 On time 

of

up to 24 hours. 

3)

Select the 

appropriate

 mode 

under

 

which

 you want the unit to 

operate

(Auto-Cool-Dry-Fan 

Only)

4)

Select the fan 

speed

 

setting.

5)

The time you 

selected

 

will

 

appear

 in the LED 

display

This is a “one-shot” timer.

  It does not continue to cycle on and off. 

It will turn the unit on (IF set by the user) ONE time.  It will turn the 

unit off (IF set by the user) ONE time.  If you require the unit to turn 

on/off again automatically, then you must set the timer again.   

Summary of Contents for dac060eb3gdb

Page 1: ...Model M od le Modelo OWNER S USE AND CARE GUIDE MODEL DANBY PRODUCTS LIMITED ONTARIO CANADA N1H 6Z9 DANBY PRODUCTS INC FINDLAY OHIO USA 45840 AIR CONDITIONER DAC060EB3GDB 25 12 13...

Page 2: ...type receptacle it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances T...

Page 3: ...st provide the original receipt NOTE THIS UNIT IS NOT DESIGNED FOR THROUGH THE WALL INSTALLATION Model No Serial No Date Purchased NEED HELP Before you call for service here are a few things you can d...

Page 4: ...plug when plugged into a matching wall outlet If you are not sure whether your wall outlet is properly grounded please consult a qualified electrician 5 The wall outlet must match the 3 prong plug on...

Page 5: ...Features Installation Instructions CAUTION Because the compressor is located on the controls side of the unit left side this side will be heavier and more awkward to manipu late Inadequate support on...

Page 6: ...he floor or ground Curtains and other objects within a room should be prevented from blocking the air flow E Be certain the proper electrical outlet is within reach of the installation Use only a sing...

Page 7: ...Cabinet Extend the shutter from the shutter frame and slide it into the shutter tabs on the side channel of the air conditioner as shown in Fig 4 Slide the shutters into the top L Shaped and bottom U...

Page 8: ...o fit the opening between the inside and outside windows then attach the safety lock to the outside window frame using one 1 2 screw See Fig 6 Window sash L Shaped Mounting Bracket Shutter clamps 1 2...

Page 9: ...re the air condi tioner will switch to Fan mode and circulate the cooled air around the room When the temperature in the room goes up the unit will switch back to cooling mode and the Auto cycle will...

Page 10: ...o select a delayed Off time of up to 24 hours 3 The time you selected will appear in the LED display The Auto On and Auto Off timer can operate during the same program by defining the Auto Off paramet...

Page 11: ...order to set the clock Press the increase or decrease arrow to adjust the clock in 1 minute intervals Holding down the increase or decrease arrow will adjust the time in 10 minute 10 Used to activate...

Page 12: ...tc batteries should be removed ni mh etc batteries standard CAN ICES 3 B_ NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of th...

Page 13: ...To get best results wash with soapy water or a neutral clean ing agent 3 Rinse the lter with clean water and dry thoroughly before re installing 1 Operate the fan alone for half a day to dry out the i...

Page 14: ...5 minutes before at tempting to restart s t r a p e s o o l n e t h g i T s t r a p e s o o L t i n u y s i o N Inadequate support Provide additional support to unit Odors Formation of mold mildew or...

Page 15: ...Canada N1H 6Z9 Telephone 519 837 0920 FAX 519 837 0449 Danby Products Inc PO Box 669 Findlay Ohio U S A 45840 Telephone 419 425 8627 FAX 419 425 8629 04 09 1 800 263 2629 Warranty Service In home Duri...

Page 16: ...ion of the service depot nearest you call the TOLL FREE number When requesting service or ordering parts always pro vide the following information Product Type Model Number Part Number Part Descriptio...